Справочник Пользователя для Regency P33-NG3

Скачать
Страница из 48
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace
Flex Liner
Exhaust
Flue
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Air Intake
Co-linear DV
Vertical Termination
Cap # 946-529
Co-Linear
Flex
Adapter
with Kit#
946-563
Outer
Pipe
with Kit#
946-563
Inner Pipe
Adapter
with Kit#
946-563
Rigid Pipe Adaptor
# 510-994
Pipe Length
45 Elbow
o
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
This appliance is designed to be attached to 
two 3" (76mm) co-linear aluminium fl ex running 
the full length of the chimney. See the Venting 
Arrangements on next page for minimum and 
maximum heights.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, 
keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must  be attached to the inlet air collar of the termination cap.
Required Parts:
Part # 
Description
946-529 
Co-linear DV Vertical 
 Termination 
Cap
948-305 
3" Flex - 35 ft.
946-563 Co-Axial 
to 
Co-Linear Adapter 
Kit
 
which contains the following: 
 
Co-linear Flex Adapter  
 
 Outer 
Pipe
 Inner 
Pipe 
Adapter 
510-994 Rigid 
Pipe 
Adaptor
945 45
o
 Elbow 
Alternate Approved Caps
980 Vertical 
Termination 
Cap
991 High 
Wind 
Cap
923GK 3" Co-linear Adapter with fl ashing
INSTALLATION
THE APPLIANCE MUST NOT BE 
CONNECTED TO A CHIMNEY FLUE 
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
FPI Cabinet and/or Flat Wall Mantles 
may be used in these applications en-
suring that clearances to combustibles 
are maintained.