CB1200-I Pellet Insert
Symptom
Possible Cause
Corrective Action
Slow or smoky start-up 
(Cont’d)
Dirty exhaust and/or venting system.
Check for ash build up in appliance, 
including behind rear panels, firebox, heat 
exchanger, exhaust blower and venting.
Feed system fails to 
start. 
Out of fuel.
#2 snap disc may be defective.
Vacuum switch not closing.  No vacuum.
Feed system jammed or blocked.
Feed spring not turning with feed motor.
Feed motor defective or not plugged in.
Check hopper, fill with fuel.
Replace snap disc.  Firebox door must be 
closed securely.
Check exhaust blower is plugged in and 
operating.
Check vacuum switch is plugged in.  
Check vacuum hose is in good condition, 
clear and connected at both ends.
Check thermocouple is in good condition 
and plugged in properly.
Make sure venting system is clean.
NOTE:
  High winds blowing into the vent-
ing system can pressurize the firebox 
causing loss of vacuum.
Empty hopper of fuel.  Use a wet/dry 
vacuum cleaner to remove remaining fuel, 
from hopper, including feed tube.
Check feed chute for obstructions.
Loosen 2 screws and jiggle feed assembly.
Check that set screw is tight on feed 
spring shaft at end of feed motor.
Check connections on feed motor, replace 
if defective.
No call light.  Appliance 
does not begin start 
sequence.
Thermostat not set to a high enough tempera-
ture.
Snap Disc #3 tripped.
No power.
Fuse blown.
Connections at thermostat and/or appliance not 
making proper contact.
Defective thermostat or thermostat wiring.
Control box defective.
Adjust thermostat above room tempera-
ture.
Reset snap disc.
Connect to power.
Replace fuse.
Check connections at thermostat and 
appliance.
Replace thermostat or wiring.
NOTE:  To test thermostat and wiring, use 
a jumper wire at the thermostat block on 
the appliance to by-pass thermostat and 
wiring.
Replace control box.
Appliance fails to shut 
off.
Call light on.
Turn thermostat off.
If call light does not go out, disconnect 
thermostat wires from appliance.  If call 
light does go out, thermostat or wires are 
defective.
Troubleshooting (Cont’d)