 E21-2 Gas Fireplace Insert
SAFETY LABEL
This is a copy of the label that accompanies 
each Regency
®
 Gas Insert. We have printed 
a copy of the contents here for your review. 
The safety label is located on the front inside 
base of the unit visible when the bottom louver 
is open.
Note: Regency
® 
units are constantly being 
improved. Check the label on the unit 
and if there is a difference, the label 
on the unit is the correct one. 
 
  Please note that with the addition 
of thermostat control and outside 
combustion air supply, this unit is 
approved for bedroom installations.
Listed: VENTED GAS FIREPLACE HEA
TER
T
e
sted to: 
ANSI Z21.88b-2003/CSA-2.33b-2003, CGA
 2.17-M91 
 Gas 
fi 
red appliance for use at high altitude.
Certifi
 ed for/Certifee pour: CANADA
 and U.S.A. Report No. 476-1428-00 (DEC. 2000)
Model/
Modele:
DO NOT REMOVE THIS LABEL/ NE P
AS ENLEVER CETTE ÉTIQUETTE
296
Serial No./ 
No de Serie
918-488
Minimum Clearances  to Combustibles/ 
Degagement Minimum Des Materiaux 
Combustibles:
Side of unit  to wall / 
Cote:
A
   9"/229mm
T
o
p of unit to 
mantle / 
Au dessus:
B   14"/355mm
MADE IN CANADA
 / F
A
BRIQUE 
AU CANADA
FPI Fireplace Products International Ltd., Delta, B.C., Canada
FIREPLACE INSERT
:             
 
    E21-NG2 
 
          E21-LP2 
 
   
APP
AREIL
 FONCTIONNANT CONCU POUR
 
  Natural Gas (Naturel Gaz) 
          Propane 
 
   ETRE INSERE DANS UN FOYER
Minimum supply pressure 
5.0"  
WC/C.E. 
(1.25 kPa) 
 
  12.0" 
WC/C.E. 
(2.99 kPa) 
Pression d’alimentation minimum
Manifold pressure high 
3.8"  
WC/C.E. 
(0.95 kPa)  
 
  1
1
.0" 
WC/C.E. 
(2.74 kPa) 
Pression tublure d'échappement élevée
Manifold pressure low 
1.1"  
WC/C.E. 
(0.27 kPa)  
   
  2.9" 
WC/C.E. 
(0.72 kPa) 
Pression  tublure d'échappement basse
Altitude 
0-2000 ft.  
      2000 - 4500 ft. 
 
 0-4500 ft. 
L'altitude
 
(0 - 610m) 
      (610 - 1372m) 
            (0-1372m)
Orifi
 ce size 
43 DMS 
 
44 DMS 
 
 
54 DMS  
 
Grandeur de l’injecteur 
Maximum input 
23,500 Btu/h 
22,000 Btu/h 
 
22,500 Btu/h 
Debit calorifi
 que 
maximum 
Minimum input 
1
1
,750 Btu/h  
1
1
,000 Btu/h 
 
1
1
,250 Btu/h 
Debit calorifi
 que 
minimum 
 
 
Duplicate Serial No.
NOT FOR USE WITH SOLID FUEL. NE P
AS UTILISER 
A
V
EC DU COMBUSTIBLE SOLIDE.
For installation into a vented non-combustible 
fi 
replace, listed factory built fi
 replace. This vented 
gas fi
 replace heater is not for use with air fi
 lters.
Ne peut etre installe que dans un foyer non
 
combustible muni d'un event. Ne pas utiliser de 
fi 
ltre à air avec ce foyer au gaz à évacuation.
W
A
RNING: This fi
 replace has been converted for use 
with a gas fi
 replace insert only and cannot be used for 
burning wood or solid fuels unless all original parts 
have been replaced, and the fi
 replace 
re-approved 
by 
the authority having jurisdiction. 
ELECTRICAL
 SUPPL
Y/ALIMENT
A
TION
 
ELECTRIQUE:1
15V60HZ less than/Moins de 2 
AMP
.
 
E21-NG2
E21-LP2
296
For the State of Massachusetts, installation 
and repair must be done by a plumber or 
gasfi tter licensed in the Commonwealth of 
Massachusetts.
For the State of Massachusetts, fl exible 
connectors shall not exceed 36 inches in 
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a 
t-handle type valve.
The State of Massachusetts requires the 
installation of a carbon monoxide alarm in 
accordance with NFPA 720 and a CO alarm 
with battery back up in the same room where 
the gas appliance is installed.