11. ELECTRICAL REQUIREMENTS
 
 
The ENVIROGAS EG-40 FPI. BV. will operate without an external electrical power supply. This model 
has a Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burners. 
 
 
The appliance when installed, must be electrically connected and grounded in accordance with local 
codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, 
SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / 
NFPA 70 in the USA. 
 
NOTE: 
•  Operation of the fan 
increases the 
efficiency and heat 
output of the unit. 
•  This unit is able to 
operate with a millivolt 
rated thermostat. 
•  To connect the 
thermostat use the 
two- (2) purple wires in 
the harness. Install the 
thermostat in series 
with the purple wires. 
 
 
 
CAUTION Label all 
wires prior to 
disconnection when 
servicing controls.  
Wiring errors can 
cause improper and 
dangerous operation.  
Verify proper 
operation after 
servicing. 
 
 
WARNING;
 Electrical grounding instructions. This appliance is equipped with a three-prong 
(grounding) plug for your protection against shock hazard, and should be plugged directly into a 
properly grounded three-prong outlet. DO NOT cut or remove the grounding prong from this plug. 
 
INSTALLING REMOTE THERMOSTAT OR WALL SWITCH  
RECOMMENDED WIRE SIZE 
for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire) 
 
1. 
Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch. 
 
2. 
Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. 
Use the terminals marked (TP/TH and TH). 
 
RECOMMENDED MAXIMUM LEAD LENGTH (TWO WIRE) 
WHEN USING WALL THERMOSTAT 
WIRE SIZE MAXIMUM 
LENGTH 
14 GAUGE 
100 FEET 
16 GAUGE 
64 FEET 
18 GAUGE 
40 FEET 
20 GAUGE 
18 FEET 
 
13