Справочник Пользователя для Roberts Gorden CTHN-60

Скачать
Страница из 48
SECTION 8: U
NITARY
 L
INEAR
 & U-T
UBE
 H
EATER
 I
NSTALLATION
  
13
8.2 Unitary Heater Requirements
CTHN unitary heaters are typically shipped as a 
burner package, fan assembly and a tube and 
accessory package. The tube and accessory 
packages contain enough tube, reflector and hanging 
parts for one unitary CTHN heater. Elbows, u-tubes, 
controls, and any other parts must be purchased 
separately.
See Page 14, Figure 13 for a general overview of a 
CTHN unitary heater. CTHN unitary heaters are 
controlled by thermostat.
Table 5 summarizes the design requirements for a 
CTHN unitary heater.
Table 5: Unitary Heater Design Requirements
Deco Grille (1' x 8' [.3 m x 2.4 m])
01363003
Bracket
01365901
End Piece
01326801
Reinforcement
01365903
Joint Piece
91406700
1' x 8' (.3 m x 2.4 m) Protective Grille
Deco Grille (2' x 4' [.6 m x 1.2 m])
01365900
Shield Frame
01370408
Reflector Side Extension 8" x 48" (20 cm x 122 cm)
01370412
Reflector Side Extension 12" x 48" (30 cm x 122 cm)
01370416
Reflector Side Extension 16" x 48" (40 cm 122 cm)
91407000
Grille, Aluminum 2' x 4' (.6 m x 1.2 m)
Protective Grille
08050001
Grille, 40" (102 cm) Protective 
08050002
Protective Grille End Cap
Fan and Pump Packages
05220000
Fan Package 40-150
05221000
Fan Package 175-200
02719105
EP-100 Pump Package
02719100
EP-100 Pump
02724700
Accessory Package
02716305
EP-201 Pump Package
01312001
EP-201 Pump
01317805
Accessory Package
02712034
EP-203 Pump Package
01312002
EP-203 Pump
01317805
Accessory Package
02723014
EP-301 Pump Package 4" (10 cm)
02730101
EP-301 Pump Assembly
02730104
Accessory Package
02723016
EP-301 Pump Package 6" (15 cm)
02730101
EP-301 Pump Assembly
02730106
Accessory Package
02723034
EP-303 Pump Package 4" (10 cm)
02730103
EP-303 Pump Assembly
02730104
Accessory Package
02723036
EP-303 Pump Package 6" (15 cm)
02730103
EP-303 Pump Assembly
02730106
Accessory Package
Pump Accessories
90430600K
Pressure Switch
Starters and Contactors
10050001
Starter, 120 Vac for EP-203, 3 Ø
10050003
Starter, 120 Vac for EP-201, 1 Ø
10050008
Starter, 120 Vac for EP-301, 1 Ø
10050009
Contactor Package-
120 Vac Coil for EP-301, 230 V, 2 HP
10050010
Starter, 120 Vac for EP-303, 3 Ø
Burner Model:
CTHN-40
CTHN-60
CTHN-80
CTHN-100 CTHN-125 CTHN-150 CTHN-175 CTHN-200
Maximum Number of Burners Allowed 
per Fan Assembly (P/N 05220000)
1
1
1
1
1
1
-
-
Maximum Number of Burners Allowed 
per Fan Assembly (P/N 05221000)
-
-
-
-
-
-
1
1
Minimum Radiant Tube Length
10' (3 m)
20' (6 m)
20' (6 m)
30' (9 m)
40' (12 m)
40' (12 m)
50' (15 m)
50' (15 m)
Minimum Distance from Burner to Elbow or 
U-Tube
10' (3 m)
10' (3 m)
10' (3 m)
15' (4.5 m) 15' (4.5 m)
20' (6 m)
20' (6 m)
20' (6 m)