Справочник Пользователя для Roberts Gorden TF-350

Скачать
Страница из 28
TF-S
ERIES
 I
NSTALLATION
, O
PERATION
 
AND
 S
ERVICE
 M
ANUAL
20 
Step 7.4.1 Coupling and Tube Assembly (Continued)
Step 7.4.2 Coupling and Tube Assembly (Continued)
Incorrect Slide Bar
position
Correct Slide Bar
dimensions
± 2" (5 cm)
Drive Slide Bar until tight.
End of Slide Bar should be
within tolerance listed below.
• Repeat Step 7.4 A - D until all tubes are assembled. See Page 20, Section 7.4.2.
Tighten slide bar as shown below
10' Typ. ± 1'
(254 cm Typ ± 25 cm)
7' 6" ± 1'
(229 cm ± 25 cm)
Model
Minimum Tube Length 
Per Side
TF-120
20’ (6 m)
TF-160
20’ (6 m)
TF-200
30’ (9 m)
TF-250
40’ (12 m)
TF-300
50’ (15 m)
TF-350
50’ (15 m)
TF-380
60’ (18 m)
See recommended venting lengths 
on Page 34, Section 9, when using 
maximum tube lengths.