Справочник Пользователя для Empire Comfort Systems DVD32FP3

Скачать
Страница из 60
23552-4-0408
Page 33
the vent end connectors.
8.  Attach the Termination Cap to the outside of the house.
9.  Prior  to  making  the  vent  connections,  apply  high  temperature 
sealant (1000 degree F min.) to the vent connections before securing 
with the band clamps provided. Note: the flue pipe end without the 
adapter is to be installed to the Termination Cap.
10.  Apply sealant to the outside of the flue pipe adapter and connect 
to the flex flue pipe. Then insert the adapter into the fireplace flue. 
Secure  flue  adapter  to  the  fireplace  flue  with  a  minimum  of  two 
screws provided. See Figure C.
11.  Attach the Outer Vent pipe to the 7" diameter Collar on the fireplace 
with a large band clamp provided. Sealant may also be used on the 
outer vent connections.
12.   Check  all  vent  connections  for  tightness.  Make  sure  horizontal 
venting  has  the  proper  rise  and  combustible  clearances  required. 
Refer to venting charts in fireplace instruction manual.
INSTALLATION
1.   Unpack vent components and check that all items are included.
2.   Check to see that the vent spacer springs are located around the flue 
vent at 8" and 12" intervals along its length.  See Figure A. If not, 
stretch the spacer springs to about 15" long and wrap them around 
the flue, then interlock the ends of each spring about 2". See Figure 
B. Maintain equal distance between spring spacers.
3.  Remove the 6-⅝" diameter Vent collar from the fireplace. Replace 
this collar with the 7" diameter Flex Vent adapter collar provided 
with the vent kit.
4.  Slide the Flex Vent flue pipe into the Outer Flex Vent pipe.
5.  Install the Wall Firestop/Thimble assembly as required through the 
wall. Refer to the venting charts in the fireplace manual to determine 
the  proper  height  and  size  of  the  vent  opening.  The  minimum 
opening should be 9" wide by 11" high. The minimum combustible 
clearance from the horizontal vent is 1" from sides and bottom, and 
3" above the vent pipe. See Figure D.
6.  In  most  cases,  after  determining  the  length  of  the  vent  that  is 
needed, it may be easier to install the flue and outer vent pipes to 
the Termination Cap first, then from the outside, feed the venting 
through the wall to the fireplace.
7.  If the venting is to long, trim off any excess vent  before attaching 
8
(203 mm)
8
(203 mm)
8
(203 mm)
4 FLEX
VENT PIPE
SPACER
SPRING
FIGURE B
””
FLEX OUTER VENT
FLEX FLUE PIPE
SPACER
SPRINGS
FIGURE A
Top of Vent
Combustibles NOT
allowed in shaded
area
1"
1"
3"
(25 mm)
7” Diameter
intake vent
4” Diameter flue
(25 mm)
(76 mm)
FIGURE D
Flex venting can be installed either vertically or horizontally 
off of the DVD Series fireplaces.  When installing a horizontal 
vent run from top connections, maintain at least ½" rise for 
every 12" of vent run. When venting horizontal off the rear 
vent connections, allow a minimum rise of 2". Refer to Figure 
43 when mounting termination near vinyl siding.
CAUTION: Always stretch and secure venting with wire or 
metal strapping to ensure that the horizontal runs do not sag.
If space permits, it is generally easier to attach venting in the 
top vent configuration.
Because of sharp edges, always use gloves when handling the 
flex vent components.
Vent connections should overlap a minimum of 1" for proper 
sealing.
Always  follow  the  general  venting  requirements  for  vent 
terminal location, vent lengths, and clearance to combustible 
materials.
The DVVK-4F FLEX VENT KIT includes the following components:
BAND CLAMP
4 DIA. FLUE
ADAPTOR
COLLAR
4 DIA. FLEX
FLUE PIPE
7 DIA. FLEX
VENT PIPE
APPLY HIGH
TEMPERATURE
SEALANT
7 DIA. INLET
ADAPTOR COLLAR
(WITH GASKET)
FIGURE C
DVVK-4F FLEX VENT INSTRUCTIONS
•  (1) Horizontal Termination Cap
•  (1) 4-foot section of Flex vent with spacers (4" flue/7" outer 
pipe)
•  (1) 4" diameter Flue adapter collar
•  (1) 7" diameter Outer Vent adapter collar
•  (1) Wall Firestop/Thimble Assembly