Справочник Пользователя для Empire Comfort Systems CIVF-25-21

Скачать
Страница из 28
Page 16
16938-3-0806
PILOT FLAME CHARACTERISTICS
Figure 15  shows a correct  pilot flame pattern. The correct flame 
will be blue and will extend beyond the thermocouple and ther-
mopile. The flame will surround the thermocouple and thermopile 
just below the tip.  A slight yellow flame may occur where the pilot 
flame and main burner flame meet.  Figure 16 shows an incorrect 
pilot flame pattern.  The incorrect pilot flame is not touching the 
thermocouple or thermopile. This will cause the thermocouple or 
thermopile to cool.  When the thermocouple cools, the heater will 
shut down.
Correct Pilot Flame Pattern
Figure 15
Incorrect Pilot Flame Pattern
Figure 16
If pilot flame pattern is incorrect, as shown in Figure 16
•  See Troubleshooting, pages 20-21.
Cleaning and Maintenance/Pilot
Oxygen Depletion Sensor Pilot  (Figure 17)
When the pilot has a large yellow tip flame, clean the Oxygen 
Depletion Sensor as follows:
1.  Clean the ODS pilot by loosening nut B from the pilot tubing.  
When  this  procedure  is  required,  grasp  nut A  with  an  open 
wrench.
2.  Blow air pressure through the holes indicated by the arrows.  
This will blow out foreign materials such as dust, lint and spider 
webs.  Tighten nut B also by grasping nut A.
Figure 17