16938-3-0806
SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS
IMPORTANT:  Operating heater where impurities in air exist may create odors.  Cleaning supplies, paint, paint remover, cigarette smoke, 
cements and glues, new carpet or textiles, etc., create fumes.  These fumes may mix with combustion air and create odors.  
  1.  When ignitor button is pressed, there is no spark at ODS/
pilot. 
a.  Ignitor electrode positioned wrong - Replace ignitor.
b.  Ignitor electrode broken - Replace ignitor.
c.  Ignitor electrode not connected to ignitor cable - Reconnect 
ignitor cable.
d.  Ignitor cable pinched or wet - Free ignitor cable if pinched 
by any metal or tubing. Keep ignitor cable dry.
e.  Broken ignitor cable - Replace ignitor cable.
f.  Bad piezo ignitor - Replace piezo ignitor.
  2.  When ignitor button is pressed, there is spark at ODS/pilot, 
but no ignition.
a.  Gas supply turned off or manual shutoff valve closed - Turn 
on gas supply or open manual shutoff valve.
b.  Control knob not in PILOT position - Turn gas control 
knob to PILOT position.
c.  Control knob not pressed in while in PILOT position - Press 
in control knob while in PILOT position.
d.  Air in gas lines when installed - Continue holding down 
control  knob.  Repeat  igniting  operation  until  air  is 
removed.
e.  Depleted gas supply - Contact local gas company.
f.  ODS/pilot is clogged - Clean ODS/pilot or replace ODS/
pilot assembly.
g.  Gas  regulator  setting  is  not  correct  -  Replace  gas 
regulator. 
  3.  ODS/pilot lights but flame goes out when control knob is 
released.
a.  Control knob not fully pressed in - Press in control knob 
fully.
b.  Control knob not pressed in long enough - After ODS/pilot 
lights, keep control knob pressed in 30 seconds.
c.  Safety  interlock  system  has  been  triggered  (thermostat 
models only) - Wait one minute for safety interlock system 
to reset. Repeat ignition operation.
d.  Manual Shutoff valve not fully open - Fully open manual 
shutoff valve.
e.  Thermocouple connection loose at control valve - Hand 
tighten until snug, then tighten 1/4 turn more.
f.  Pilot  flame  not  touching  thermocouple,  which  allows 
thermocouple to cool, causing pilot flame to go out. This 
problem could be caused by either 1) low gas pressure 
-  Contact  local  gas  company  or  2)  dirty  or  partially 
clogged ODS/pilot - Clean ODS/pilot or replace ODS/pilot 
assembly.
g.  Thermocouple damaged - Replace thermocouple.
h.  Control valve damaged - Replace control valve.
  4.  Main burner does not light after ODS/pilot is lit.
a.  Main burner orifice clogged - Clean main burner or replace 
main burner orifice.
b.  Main burner orifice diameter is too small - Replace main 
burner orifice.
c.  Inlet  gas  pressure  is  too  low  -  Contact  local  gas 
company.
  5.  Pilot burning, no gas to burner, valve knob "ON", on/off 
switch "ON."
a.  "On/Off"  switch,  wall  switch,  remote  control  or  wires 
defective  -  Check  "on/off"  switch  and  wires  for  proper 
connections. Place jumper wires across terminal at switch 
- if burner comes on, replace defective switch. If OK, place 
jumper wires across switch wires at gas valve-if burner 
comes on, wires are faulty or connections are bad.
b.  Thermopile  may  not  be  generating  sufficient  millivolts 
- If the pilot flame is not close enough physically to the 
thermopile, clean the ODS/pilot.
  - Be sure the wire connections from the thermopile at the 
gas valve terminals are tight and the thermopile is fully 
inserted into the pilot bracket.
  - Check the thermopile with a millivolt meter. Take the 
reading at TH-TP & TP terminals of the gas valve. The 
meter should read 350 millivolts minimum, while holding 
the valve knob depressed in the PILOT position, with the 
pilot lit, and the ON/OFF switch in the OFF position. Replace 
the faulty thermopile if the reading is below the specified 
minimum.
  - With the pilot in the ON position, disconnect the thermopile 
leads from the valve. Take a reading at the thermopile leads. 
The reading should be 350 millivolts minimum. Replace 
the thermopile if the reading is below the minimum.
c.  Defective valve - Turn valve knob to "ON." Place ON/OFF 
switch to "ON." Check with millivolt meter at thermopile 
terminals.  Millivolt  meter  should  read  greater  than  200 
millivolts. If the reading is okay and the main burner does 
not ignite, replace the gas valve
d.  Plugged main burner orifice - Check main burner orifice 
for blockage and remove. 
  6.  Delayed ignition of main burner.
a.  Manifold  pressure  is  too  low  -  Contact  local  gas 
company.
b.  Main burner orifice clogged - Clean main burner and main 
burner orifice.
  7.  If burning at main burner orifice occurs (a loud, roaring 
blow torch noise).
a.  You must turn off burner assembly and contact a qualified 
service person.
b.  Main burner orifice is clogged or damaged – Clean main 
burner  and  main  burner  orifice  or  replace  main  burner 
orifice.
c.  Damaged main burner – Replace damaged main burner.
d.  Gas regulator defective – Replace gas regulator.
  8.  Yellow flame in front section of main burner during main 
burner combustion.
a.  Not enough air - Check main burner for dirt and debris. If 
found, clean main burner.
b.  Gas regulator defective - replace gas regulator.