Specifications
System 
Module 1 
Module 2
Unit Type
PUHY-P168TSHMU-A
PUHY-P96THMU-A
PUHY-P72THMU-A
Nominal Cooling Capacity
Btu/h
168,000
96,000
72,000
Nominal Heating Capacity
Btu/h
188,000
108,000
80,000
External Dimensions (H x W x D) In. / mm
Refer to Module Data
65 x 36-1/4 x 29-15/16 /  
1,650 x 920 x 760
65 x 36-1/4 x 29-15/16 / 
1,650 x 920 x 760
Net Weight
Lbs. / kg
882 / 400
441 / 200
441 / 200
Electrical Power Requirements
Voltage, Phase, Hertz
Refer to Module Data**
208/230V, 3-phase, 60Hz
Cooling Power Input
kW
14.11
Refer to System Data
Heating Power Input
kW
14.73
Cooling Current (208/230V)
A
43.5 / 39.3
Refer to System Data
Heating Current (208/230V)
A
45.4 / 41.0
Minimum Circuit Ampacity 
(MCA)**
A
Refer to Module Data**
35 / 32**
23 / 21**
Maximum Overcurrent  
Protection (MOCP)**
A
Refer to Module Data**
40 / 40**
30 / 30**
Piping Diameter
Refer to System Data
From Twinning Kit to Indoor Units 
(Brazed) (In. / mm)
Liquid (High Pressure)
5/8 / 15.88
Gas (Low Pressure)
1-1/8 / 28.58
From Modules to Twinning Kit 
(Brazed) (In. / mm)
Liquid (High Pressure)
Refer to Module Data
3/8 / 9.52
3/8 / 9.52
Gas (Low Pressure)
7/8 / 22.2
3/4 / 19.05
Indoor Unit
Total Capacity
50 to 130% of ODUs
Refer to System Data
Model / Quantity
P06 ~ P96 / 1 to 36
Sound Pressure Levels
dB(A)
61.0
58.0
58.0
Fan
Refer to Module Data
Type x Quantity
Propeller Fan x 1
Propeller Fan x 1
Airflow Rate
CFM
7,050
7,050
Direct-drive Inverter Motor Output
kW
0.92
0.92
Compressor Operating Range
8% to 100%
Refer to System Data
Compressor Type x Quantity
Refer to Module Data
Inverter-driven Scroll Hermetic x 1 Inverter-driven Scroll Hermetic x 1
Compressor Motor Output
kW
6.8
5.1
Compressor Crankcase Heater
kW
0.051
0.051
Refrigerant
Refer to Module Data
R410A
Lubricant
MEL32
High-pressure Protection Device
Refer to Module Data
601 psi / 4.15 MPa
601 psi / 4.15 MPa
Compressor / Fan Protection Device
Overheat Protection / Thermal Switch Overheat Protection / Thermal Switch
Inverter Protection Device
Overheat / Overcurrent Protection Overheat / Overcurrent Protection
Blue Fin Anti-corrosion Protection: Cellulose- and polyurethane-resin coating treatment applied to condenser coil that protects it from air contaminants;  
≥1μm thick; Salt Spray Test Method - no unusual rust development to 480 hours.
Outdoor Unit:
 14-TON PUHY-P168TSHMU-A
(Consists of One PUHY-P96THMU-A, One PUHY-P72THMU-A, and One CMY-Y100VBK2 Twinning Kit)
OUTDOOR VRFZ HEAT PUMP SYSTEM FEATURES
• 3-phase, 208/230V systems
• Modular variable refrigerant flow zoning (VRFZ) systems; 
  smaller capacity units can be piped together to form a single, 
  large-capacity two-pipe system
• Compact size for each outdoor module; can be transported 
  through standard-sized doorways for installation
• Required Twinning Kit allows for easy field piping connection
• Selectable fan static, 0.12 or 0.24"WG external static  
  pressure; factory set to 0"WG
• Maximum 
Total Refrigerant Piping Length: 3,280'; Maximum  
  Refrigerant Line Length: 541'; Maximum Control Wiring 
  Length: 1,650'
• Connects to CITY MULTI indoor units; controlled via  
  CITY MULTI Controls Network (CMCN)
• External finish: Pre-coated Galvanized-steel Sheets
• Operating Temperature Range 
  Cooling (Outdoor): 23° ~ 109°F (-5° ~ +43°C) DB
  Heating (Outdoor): -4° ~ +60°F (-20° ~ +16°C) WB
** Each individual module requires a separate electrical connection. Reference electrical data for each individual module.
PUHY-P72THMU-A
OPTIONAL PARTS
□ Twinning Kit*.…………………………………...…….CMY-Y100VBK2
□ T-Branch Joint (≤ 72,000 Btu/h)………………..........CMY-Y102S-G2 
□ T-Branch Joint (≤ 144,000 Btu/h)……………….…....CMY-Y102L-G2
□ T-Branch Joint (≤ 234,000 Btu/h)………………..........CMY-Y202-G2
□ Header (4-Branch; ≤ 72,000 Btu/h)........………………CMY-Y104-G
□ Header (8-Branch; ≤ 144,000 Btu/h)......………………CMY-Y108-G
□ Header (10-Branch; ≤ 234,000 Btu/h)....……………….CMY-Y1010-G
* Twinning Kit is necessary to combine the refrigerant flows of the  
   modules and is included in the outdoor unit set. 
PUHY-P96THMU-A