Справочник Пользователя для Desa VyS18NC

Скачать
Страница из 32
www.desatech.com
124452-01A
21
TROUbLESHOOTING
 WARNING: Turn off and unplug heater and let cool before servicing. 
Only a qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor  cable  pinched  or 
wet
3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned 
wrong
1. Gas  supply  turned  off  or 
equipment  shutoff  valve 
closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Depleted gas supply (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas  regulator  setting  is 
not correct
OBSERVED PROBLEM
When control knob is pressed 
in and turned to PILOT, there 
is not spark at ODS/pilot
When control knob is pressed 
in and turned to PILOT, there 
is  spark  at  ODS/pilot  but  no 
ignition
REMEDY 
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Replace valve
4. Replace valve
5. Replace pilot
6. Reposition ignitor electrode
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while 
in PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact  local  propane/LP 
gas company
6. Clean ODS/pilot (see Clean-
ing and Maintenance, page 
19)  or  replace  ODS/pilot 
assembly
7. Replace gas regulator