Справочник Пользователя для Carrier 50XT

Скачать
Страница из 38
30
Wet coil air delivery -- low stage
208/230 VOLT
UNIT
SIZE
SYSTEM SETTING
EXTERNAL STATIC PRESSURE (in. wc)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
024
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
525
525
525
525
525
525
525
525
525
525
MAX
600
600
600
600
600
600
600
600
600
600
030
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
613
613
613
613
613
613
613
613
613
613
MAX
700
700
700
700
700
700
700
700
700
700
036
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
743
743
743
743
743
743
743
743
743
743
MAX
850
850
850
850
850
850
850
850
850
850
042
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
853
853
853
853
853
853
853
853
853
853
MAX
975
975
975
975
975
975
975
975
975
975
048
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
963
963
963
963
963
963
963
963
963
963
MAX
1100
1100
1100
1100
1100
1100
1100
1100
1100
1100
060
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
MAX
1372
1372
1372
1372
1372
1372
1372
1372
1372
1372
Wet coil air delivery -- high stage
208/230 VOLT
UNIT
SIZE
SYSTEM SETTING
EXTERNAL STATIC PRESSURE (in. wc)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
024
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
700
700
700
700
700
700
700
700
700
700
MAX
800
800
800
800
800
800
800
800
800
800
030
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
875
875
875
875
875
875
875
875
875
875
MAX
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
036
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
1050
1050
1050
1050
1050
1050
1050
1050
1050
1050
MAX
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
042
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
1225
1225
1225
1225
1225
1225
1225
1225
1225
1225
MAX
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
048
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
1400
1400
1400
1400
1400
1400
1400
1400
1400
1400
MAX
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
060
COMFORT (Default)
Variable based on Comfort Settings
EFFICIENCY
1750
1750
1750
1750
1750
1750
1750
1750
1750
1750
MAX
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
Air delivery values are based on operating voltage of 230v, and wet coil. Filter and electric heater will not change air delivery values.
NOTES:
1. See User Interface instructions for more information on Max, Efficiency, and Comfort Settings
2. Efficiency Setting operates at 350 cfm/ton (nominal) and Max Setting operates at 400 cfm/ton (nominal)