Y Configuration - Left Return/Back Discharge 
W Configuration - Left Return/Right Discharge - Air Coil Opening 
W Configuration - Left Return/Right Discharge - Air Coil Opening 
P Configuration - Right Return/Back Discharge - Air Coil Opening 
N Configuration - Right Return/Left Discharge - Air Coil Opening 
N Configuration - Right Return/Left Discharge - Air Coil Opening 
Left 
View 
Right 
View 
Size
Right 
View 
ASP
BSP
Q
P
O
R
Blower
Outlet
Air Coil 
S
ide
C
A
Y
F
ront
X
Z
C
P
A
R
O
Q
BSP
Left
Discharge
Back
Discharge
Condensate
3/4” FPT
H
CSP
Front
2  Service Access
Right Return
2  Service Access
3.25”
G
F
E
D
CAP
J
K
L
A
Power Supply
3/4” Knockout
1/2” 
Knockout
Low Voltage 
1/2” Knockout
Front
CSP
ASP
Left Return
Right
Discharge
Back
Discharge
Condensate
3/4” FPT
H
2  Service 
Access
2  Service Access
Air Coil 
S
ide
Blower
Outlet
BSP
P
M
N
O
Blower
Outlet
S
U
V
C T
B
CSP
Front
Front
Air Coil
1.1”
C
Air Coil
ASP
S
B
T
Front
CSP
M
BSP
Blower
Outlet
O
P
N
3.25”
1.6”
, 072
NOTES:
1. Condensate connection is stainless steel 
3
/
4
 in. female pipe thread (FPT).
2. Unit shipped with top and bottom filter rack and is not suitable for duct connection without
additional support.
3. Discharge flange is factory-installed.
4. Hanger kit is factory-installed.
5. Shaded areas are recommended service areas, not required.
6. Discharge can be modified in field. Return cannot be modified.
AIRFLOW CONFIGURATION
50PTH
UNIT
OVERALL CABINET 
(in.)
WATER CONNECTIONS (in.)
WATER 
CONNEC-
TIONS (in.) 
- UNITS 
WITH HWR
ELECTRICAL
KNOCKOUTS (in.)
DISCHARGE CONNECTIONS (in.)
DUCT FLANGE INSTALLED 
(
 0.10 in.)
RETURN CONNECTION
USING AIR COIL 
OPENING (in.)
A
Width
B
Depth
C
Height
1
2
3
4
5
Loop
Water
FPT
(in.)
HWG
FPT
(in.)
1
2
J
1
/
2
-in.
Cond
K
1
/
2
-in.
Cond
L
3
/
4
-in.
Cond
M
(LH 
rtn)
N
O
Supply
Height
P
Supply
Width
Q
(RH 
rtn)
R
S
Return
Width
T
Return
Height
U
V
D
In
E
Out
F
HWG
In
G
HWG
Out
H
Cond-
ensate
Loop 
in D
Loop 
out E
Low
Voltage
Ext
Pump
Power
Supply
026
22.4
62.2
19.3
2.1
10.0
13.9
16.9
3.5
3
/
4
1
/
2
2.1
10.0
3.6
6.1
8.6
3.6 2.0
12.5
15.5
3.6 2.0
33.8
16.2
2.3 1.5
038
25.4
71.2
21.3
3.4
10.8
14.6
18.9
3.4
3
/
4
1
/
2
5.96 13.13
3.4
6.1
8.6
3.1 1.2
19.0
17.5
3.1 1.0
34.8
18.2
3.1 1.5
049
25.4
76.2
21.3
3.4
10.8
15.6
18.9
3.4
1
1
/
2
5.96 13.13
3.6
6.1
8.6
3.1 1.2
19.0
17.5
3.1 1.0
39.8
18.2
3.1 1.5
064,072
25.4
81.2
21.3
3.4
10.8
15.6
18.9
3.4
1
1
/
2
5.96 13.13
3.6
6.1
8.6
3.1 1.2
19.0
17.5
3.1 1.0
44.8
18.2
3.1 1.5
CODE
RETURN
DISCHARGE
N
Right
Left
P
Right
Back
W
Left
Right
Y
Left
Back
LEGEND
ASP
— Alternate Service Panel
BSP
— Blower Service Panel
CAP — Control Access Panel
CSP
— Compressor Service Panel
FPT
— Female Pipe Thread
HWG — Hot Water Generator
HWR — Hot Water Reheat
Fig. 1 — 50PTH026-072 Dimensional Data