Model
Compensator
 Pressure 
Setting Psig
Table 9. Load sensing compensator adjustment range.
Lockwire
Standby
Pressure
P2
P @
USgpm
(P2-P1)
P @ Compensator
Cracking
Pressure (P2-P1)
PVE19*-*-**-CV-10
PVE19*-*-**-CVP-12
PVE19*-*-**-CVPC-12
PVE12*-*-**-C**VPD41
PVE21*-*-**-CV-10
PVE21*-*-**-CVP-12
PVE21*-*-**-CVPC-12
Not Applicable
Not Applicable
3000
2700
3000
2700
Yes
Yes
Yes
250
psi
Max.
550
psi
Max.
160 psi
± 20 psi
4 USgpm
+20
–30
+20
–30
+20
–30
160
psi
360
psi
350
psi
PVE12*-*-**-C**VPC24
PVE12*-*-**-C**VP11
3000
3000
3000
Yes
Yes
250
psi
Max.
900
psi
Max.
500
psi
Max.
+20
–30
600
psi
+20
–30
160
psi
350 psi
± 25 psi
4 USgpm
600 psi
± 50 psi
4 USgpm
160 psi
± 20 psi
6.5 USgpm
350 psi
± 25 psi
6.5 USgpm