60°
ADJUSTING THE VERTICAL AIRFLOW DIRECTION
Please operate with the remote controller. (Moving by hands may cause malfunction.)  
Set automatically
•  Air conditioner automatically set to the suitable 
angle for each operation (Horizontal air deflector 
only. The angle of the vertical air deflector is set to 
the front). Usually vertical airflow direction control 
is not required.
•  If room temperature and humidity continue to be 
high during cooling, dehumidifying or dry cool 
operation, the angle of horizontal air deflector may 
change to prevent dripping of condensed water.
Swing
angle
About 
Horizontal
Vertical airflow swing
•  When the 
 (VERTICAL AIRFLOW) button is pressed, 
a short beep sounds and the vertical air deflector repeats 
swinging.
•  When the air conditioner stops operation, the swing of the 
vertical air deflector also stops and the air outlet closes.
•  If the operation resumes, the vertical air deflector is 
automatically set to the suitable angle for each operation.
•  Even if the swing mode is set, the vertical air deflector may 
stop swinging depending on the room temperature and 
humidity. (Page 25)
  (It may take approximately 10 seconds for the air deflector 
to start moving. This is due to the checking operation to set 
the air deflector to the correct angle.)
Vertical air flow of your preference
•  To set the vertical airflow direction to your desired angle, press the 
 (VERTICAL 
AIRFLOW) button to move the vertical air deflector, and press the 
 (VERTICAL 
AIRFLOW) button again to stop air deflector at your desired angle.
Press the 
 (VERTICAL AIRFLOW) button.
•  A short beep sounds and the vertical air deflector repeats swinging. 
  (Vertical airflow swing)
Press the 
 (VERTICAL AIRFLOW) button again at your preferred angle.
•  The swing stops at the position where the button is pressed.
•  The air outlet closes if the operation stops. The horizontal air deflector will return to 
the preset position when the operation resumes.
•  If the operation mode is changed, the horizontal air deflector will automatically be 
set to the proper angle suitable for the newly set mode.
 CAUTION
DO not operate long hours with cooling, dehumidifying, dry operation, airflow swing operation nor 
the vertical air deflector in downward state.
Some dew may form on the vertical air deflector and drop which may wet your furniture.
ENGLISHDEUTSCH
FRANÇAIS
IT
ALIANO
SP
ANISH
POR
TUGUÊS
∂ÏÏËÓÈο
РУССКИЙ
– 24 –
C
M
Y
CM
MY
CY
CMY
K
EN_24.ai   2010-7-7   15:20:29
EN_24.ai   2010-7-7   15:20:29
15°
10°
50°
Cooling
operation
Heating
operation
Dehumidifying/
Dry Cool operation
About 
About 
About