Справочник Пользователя для Hitachi RAS-SX10HAK / RAC-SX10HAK

Скачать
Страница из 96
 
1
2
3
4
2
3
MAINTENANCE (continued) 
Maintenance of electric dust collector electrodes
Stop the operation with the remote controller 
and unplug the power supply (or turn off the 
circuit breaker).
Slowly open the vertical air deflectors using 
both hands.
 CAUTION
•  Be sure to open slowly using both hands as shown 
in the illustration. 
  Otherwise, it may cause malfunction.
•  Do not use excessive force to move the air deflector
beyond the stopper located below it.
  Otherwise, it may cause malfunction.
Remove the dirt on the electric dust collector 
electrodes with a toothbrush.
• Be sure to use a dry toothbrush.
• Lightly brushed off the dust.
Horizontal air 
deflectors
Electric dust collector electrodes
 CAUTION
• Do not touch the electric dust collector electrodes while the air conditioner is in operation 
  
High voltage generated at these parts could result in electrical shock.
• Do not splash or direct water to the electric dust collector electrodes  
  
It may cause short circuit or malfunction.
– 38 –
Turn on the power supply.
(or turn on the circuit breaker)
C
M
Y
CM
MY
CY
CMY
K
EN_38.ai   2010-6-28   17:46:39