Installation of Indoor Unit 
 
Earthing Requirements 
(1)
 Mounting plate should be installed horizontally with slight slant to water tray’s outlet for smooth drainage 
of water. 
(2)
 Fix the mounting plate on the wall with screws ensuring good fit to wall stud or masonry.  
(3)
 Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the 
weight should be evenly shared by every screw. 
 
 
 
 
 
 
Drill Piping Hole 
(1)
 Slant the piping hole (55 degrees) on the wall slightly downward to 
the outdoor side
.
  
(2)
 Insert the piping-hole sleeve into the hole to prevent the connection 
piping and wiring from being damaged when passing through the hole. 
 
 
 
Installation of Drain Hose 
(1)
 Connect the drain hose to the outlet pipe of the indoor unit. Bind 
the joint with rubber belt (tape).  
 
 
 
 
 
 
(2)
 Put the drain hose into insulating tube.  
 
 
 
 
 
(3)
  Wrap the insulating tube with wide rubber belt to prevent 
the shift of insulating tube. Slant the drain hose downward slightly for 
smooth drainage of condensing water. 
 
 
 
 
Note:
 The insulating tube should be connected reliably with 
the sleeve outside the outlet pipe. The drain hose should be 
slanted downward slightly, without distortion, bulge or 
fluctuation. Do not submerge the outlet in water.  
 
 
sleeve