Figure 8 - Fan and Motor Reversed for 
Cleaning
Fan
Terminal 
Block
Figure 7 - Removing Fan and Motor
Top Cover
SERVICE PROCEDURES
  warninG:  never  service 
heater  while  it  is  plugged  in, 
connected  to  propane  supply, 
operating or hot. Severe burns 
and electrical shock can occur. 
CleaninG Fan
Clean  fan  every  500  hours  of  operation  or 
as needed.
1.  Remove screws on top cover using 5/16" 
nut-driver or Phillips head screw driver.
.  Remove top cover.
3.  Detach the  black motor wires from ter-
minal block under top cover. Be sure to 
detach only wires coming from motor.
4.  Remove  fan  guard  from  rear  of  heater. 
Fan guard will snap out of shell.
5.  Reach into rear of heater shell. Carefully 
pull motor wires through hole in bracket. 
Note:  Pull  wires  through  hole  one  at  a 
time.
6.  Remove screws holding motor mount to 
shell. Use 5/16" nut driver or Phillips head 
screw driver.
7.  Carefully pull motor and fan out of shell. 
IMPORTANT: Be careful not to damage 
fan. Do not set motor and fan down with 
the weight resting on fan. This could dam-
age fan pitch. 
8.  Turn motor and fan around. Place motor 
and fan into shell backwards. Note: Motor 
will go into shell first (see Figure 8).
9.  Line up rear mounting holes in shell with 
first hole on each side of motor mount (see 
Figure 8). Note: When holes are lined up, 
fan should be outside of shell.
10. Holding mounting screws, carefully reach 
through fan blades into rear of heater. Be 
careful  not  to  damage  fan  pitch.  Insert 
screw  through  motor  mount  and  shell. 
With free hand, attach screw finger tight. 
Repeat process for other mounting hole.
11. Use 1/8" hex wrench to loosen setscrew 
which holds fan to motor shaft (see Fig-
ure 9, page 9).
1. Slip fan off motor shaft.
13. Clean fan using soft cloth moistened with 
a cleaning solvent.
Motor
Motor Mounting 
Bracket
Motor Mounting 
Bracket
Hole in 