DRAIN PAN VALVE 
During the cooling mode of operation, condensate which  
collects in the drain pan is picked up by the condenser fan  
blade and sprayed onto the condenser coil. This assists 
in cooling the refrigerant plus evaporating the water. 
During the heating mode of operation, it is necessary that 
water be removed to prevent it from freezing during cold 
outside  temperatures.  This  could  cause  the  condenser 
fan blade to freeze in the accumulated water and prevent 
it from turning.  
To provide a means of draining this water, a bellows type 
drain valve is installed over a drain opening in the base 
pan. 
This  valve  is  temperature  sensitive  and  will  open  when 
the  outside  temperature  reaches  40°F.  The  valve  will 
close  gradually  as  the  temperature  rises  above  40°F  to 
fully close at 60°F.  
TESTING THE HEATING ELEMENTS AND 
LIMIT SWITCHES 
Testing  of  the  heating  elements  can  be  made  with  an 
ohmmeter  or  continuity  tester  across  the  terminals  after 
the power wires have been removed. Test the limit switch 
for  continuity  across  its  input  and  output  terminals.Test 
below the limit switch’s reset temperature.
HEATER ELEMENTS AND LIMIT SWITCHES’
SPECIFICATIONS
All  heat  pumps  and  electric  heat  models  are  equipped 
with  a  heating  element  and  a  limit  switch  (bimetal  ther-
mostat).  The  limit  is  in  series  with  the  element  and  will 
interrupt the power at a designed temperature.
 
Should the blower motor fail, fi lter become clogged or air-
fl ow be restricted etc., the high limit switch will open and 
interrupt the power to the heater before reaching an un-
safe temperature condition.
 
 
                
Bellows Assembly 
Drain Pan Valve  
COMPONENTS TESTING (Continued)
ELECTRIC SHOCK HAZARD 
WARNING
Disconnect  power  to  the  unit  before 
servicing.  Failure  to  follow  this  warning 
could result in serious injury or death.