Справочник Пользователя для Toshiba RAV-SM1403AT-E1

Скачать
Страница из 93
– 78 –
1
Push 
SET
 + 
CL
 + 
TEST
 buttons simultaneously
for 4 seconds or more.
2
(
 Line address)
Using the temperature setup 
 / 
 buttons,
set 
12
12
12
12
12
 
 to the CODE No.
3
Using timer time   /   buttons, set the line address.
4
Push 
SET
 button. (OK when display goes on.)
5
(
 Indoor unit address)
Using the temperature setup 
 / 
 buttons, set 
13
13
13
13
13
 
 to the CODE No.
6
Using timer time   /   buttons, set 1 to the line address.
7
Push 
SET
 button. (OK when display goes on.)
8
(
 Group address)
Using the temperature setup 
 / 
 buttons, set 
14
14
14
14
14
 
 to the CODE No.
9
Using timer time   /   buttons, set 
0000
0000
0000
0000
0000
 
to Individual, 
0001
0001
0001
0001
0001
 
to Master unit, and 
0002
0002
0002
0002
0002
 
to sub unit.
10
Push 
SET
 button. (OK when display goes on.)
11
Push 
TEST
 button.
Setup completes. (The status returns to the usual stop status.)
10-5. Confirmation of Indoor Unit No. Position
1. To know the indoor unit addresses though position of the indoor unit body is recognized
• In case of individual operation (Wired remote controller : indoor unit = 1 : 1)
(Follow to the procedure during operation)
<Procedure>
1
Push 
ON / OFF
 button if the unit stops.
2
Push 
UNIT  LOUVER
 button.
Unit No. 
1-1
1-1
1-1
1-1
1-1
 is displayed on LCD.
(It disappears after several seconds.)
The displayed unit No. indicate line address and
indoor unit address.
(When other indoor units are connected to the
identical remote controller (Group control unit), other
unit numbers are also displayed every pushing
UNIT  LOUVER
 button.