J806
J800, J801, J802
Capacitor
MCC-5009
IC800
L01
C12
C13
C14
14.  SET UP OF SERVICE P.C. BOARD
Before replacing the P.C. board, set up the P.C. board according to the following table.
Caution
  When repaired P.C. board should be electric discharge of capacitor. (C12, C13, C14)
APPLICATION MODELS :
RAS-10SAVP-E, RAS-13SAVP-E, RAS-16SAVP-E
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
JUMPER SET UP :
As shown in the following table, cut jumper lead wire (J800, J801, J802, J806) according to each model.
LOCATION OF JUMPER LEAD WIRE :
Corresponding
model
Jumper lead wire
J800
Jumper lead wire
J801
Jumper lead wire
J802
Jumper lead wire
J806
ORIGINAL
RAS-
RAS-
RAS-
RAS-
RAS-
RAS-
10SAVP-E
13SAVP-E
16SAVP-E
10SAVP-ND 13SAVP-ND 16SAVP-ND
Close
Close
Close
Open
Open
Close
Close
 (Original)
(Original)
(Original)
(Cut)
(Cut)
(Original)
(Original)
Close
Close
Open
Close
Open
Close
Open
 (Original)
(Original)
(Cut)
(Original)
(Cut)
(Original)
(Cut)
Close
Close
Close
Close
Close
Open
Close
 (Original)
(Original)
(Original)
(Original)
(Original)
(Cut)
(Original)
Close
Close
Close
Close
Close
Close
Close
 (Original)
(Original)
(Original)
(Original)
(Original)
(Original)