Справочник Пользователя для Toshiba RAS-B10SKVP-E

Скачать
Страница из 119
– 37 –
Heating operation/
AUTO (HEAT)
Powerful
SLEEP MODE operation
Dry operation
In case that the following temp. is obtained 
during 12 minutes or 12 to 25 minutes 
from start of heating operation: 
Room temp. (Ta) < Set temp. (Tsc) –3.0 
In case that the following temp. is 
obtained during 12 to 25 minutes from 
start of heating operation: 
Room temp. (Ta) > Set temp. (Tsc) –3.0
or when 25 minutes or more passed from 
start of heating operation
Initial setting of 
“Heating storage position”
Louver : 
Directs downward (81˚)
“Heating storage position”
Louver : 
Directs downward (81˚)
“Heating storage position”
Louver : Directs downward (81˚)
“Cooling storage position”
Louver : Directs downward (23˚)
Only when the operation frequency is 
COOL Min–Hz under condition of 
Room temp. (Ta) < Set temp. (Tsc) +1.0 
Powerful
Cooling operation/AUTO (COOL)
SLEEP MODE operation
Initial setting of “Cooling storage position”
Louver : Directs downward (23˚)
“Cooling storage position”
Louver : Directs downward (23˚)
Louver : Directs downward (8˚)
Initial setting of “Cooling storage position”
Louver : Directs downward (23˚)
Louver : Directs downward (8˚)
Louver angle
Horizontal 
(0˚)
Horizontal
blowing
Inclined
blowing
Blowing
downward
Air direction
Inclined
blowing
Horizontal
blowing
Item
9. Louver control
1) Louver
position
2) Air direction adjustment
3) Swing
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
• The position is automatically controlled according to the operation mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer, and the louver returns to the
stored position when the next operation is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
When the louver closes fully, it directs approx. 28° upward.
1) Louver position in cooling operation
2) Louver position in heating operation
3) Louver position in dry operation
• Swing operation is performed in width 35° with the stop position as the
center.
• If the stop position exceeds either upper or lower limit position, swing
operation is performed in width 35° from the limit which the stop
position exceeded.
Description
• The louver position can
be arbitrarily set up by
pushing [FIX] button.
• Swing
When pushing [SWING]
button during operation,
the louver starts
swinging.