10. INSTALLATION PROCEDURE
10-1.Installation Diagram of Indoor and Outdoor Units
Before installing the wireless 
remote control
100 mm or
more from
wall
Insert the cushion between 
the indoor unit and wall, and 
tilt the indoor unit for better 
installation work.
Make sure the drain hose is 
sloped downward.
The auxiliary piping can be 
connected at the left, rear 
left, rear right, right, bottom 
right or bottom left as shown 
below.
Extension drain hose
(Option: RB–821SW)
6 mm thick heat resisting 
polyethylene foam
80 mm or more only 
when unobstructed to 
the front and both sides
 Remote control holder
(Mounting holes on both 
left and right sides)
 Remote control 
holder mounting 
screw
For the rear left and left 
piping
Wall
Do not allow the drain hose 
to become slack.
Cut the piping 
hole slightly 
sloped 
Insulate the refrigerant pipes 
separately, not together.
• With the remote control 
cover removed, correctly 
load the supplied batteries 
while observing their 
polarity.
Cover
 Wireless remote control
 Batteries
 Wireless remote control
Hook
 Installation 
plate
 Zeolite-plus filter
 Plasma pure filter
 Shield pipe 
(for extension 
drain hose)
Z
Hook
Bottom right
Rear 
right
Right
Left
Bottom left
Rear left
47 mm or more
74 mm or 
more
140 mm or 
more
250 mm or 
more from wall
200 mm or 
more
50 mm or more 
from wall
 Mounting screw
Hook
Air filters
In principle,
leave open
As shown in the 
figure, position 
power cord and 
connecting 
cable 
downward, and 
lead out along 
piping 
connection port.
When installing the 
outdoor unit, leave 
open in at least two 
of directions (A), 
(B), (C) and (D) 
shown in the right 
figure.
Ensure sufficient 
space to allow 
drainage
(A)
(B)
(C)
(D)
power cord
Y
a
g
e
f
b
d
h
b
c
In case the piping is installed above 
the ceiling, it shall be covered with 
thicker insulating material 
(polyethylene form, 10 mm-thick)