Справочник Пользователя для Toshiba RAS-B13SKVP-E
– 47 –
OPERATION lamp
ON 8˚C HEAT
operation starts
Shifts to [8˚C]
HEAT operation.
Push button
During stop
During operation
Push [8˚C] button.
Push [8˚C] button.
Push button
Operation stop
Operation stop
Do you stop 8˚C
HEAT operation?
Do you stop 8˚C
HEAT operation?
Push [8˚C]
button.
Push [8˚C]
button.
YES
YES
NO
NO
Item
20. 8°C HEAT operation
(-ND model only)
Operation flow and applicable data, etc.
Pushing the [8°C] button on the remote
controller starts HEAT operation with set
temp. 8°C. The air conditioner is controlled
according to the room temperature 8°C as a
standard.
controller starts HEAT operation with set
temp. 8°C. The air conditioner is controlled
according to the room temperature 8°C as a
standard.
The room temperature may be a little off the
room temperature 8°C due to the room size
or installation condition of the unit.
room temperature 8°C due to the room size
or installation condition of the unit.
Contents of which setting can be changed during 8°C HEAT operation
SWING (louver swing)
FIX (louver position)
FAN (fan speed)
PURE (pure operation)
Description
<Start>
During stop of air conditioner
• Pushing [8°C] button turns on the Operation
lamp (Green) of the main unit is turned on
and the HEAT operation of set temp. 8°C
starts.
and the HEAT operation of set temp. 8°C
starts.
During operation of air conditioner
• Pushing [8°C] button shifts the operation to
HEAT operation with set temp. 8°C.
• In case of COOL (including automatic
cooling) or DRY operation, 8°C HEAT
operation starts approx. 3 minutes after
operation stop.
operation starts approx. 3 minutes after
operation stop.
In case of HEAT operation, the operation
shifts to 8°C HEAT operation as it is.
shifts to 8°C HEAT operation as it is.
∗
If the timer operation has been set up before
8°C HEAT operation, the setup is released
when 8°C HEAT operation starts.
8°C HEAT operation, the setup is released
when 8°C HEAT operation starts.
∗
When [8°C] button is pushed again during
8°C HEAT operation, the status returns to
that before 8°C HEAT operation.
8°C HEAT operation, the status returns to
that before 8°C HEAT operation.
∗
When the operation shifts from 8°C HEAT
operation to the normal HEAT operation, the
cold draft preventive control works.
operation to the normal HEAT operation, the
cold draft preventive control works.
Therefore the hot air may blow out after
approx. 5 minutes.
approx. 5 minutes.
<Stop>
Pushing