1 Installation plate
Insert the cushion between 
the indoor unit and wall, and 
tilt the indoor unit for better 
installation work.
Make sure the drain hose is 
sloped downward.
The auxiliary piping can be 
connected at the left, rear left, 
rear right, right, bottom right or 
bottom left as shown below.
• Indoor units connectable with a multi-system outdoor unit (Other indoor units are unavailable.)
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E
• When using a multi-system outdoor unit, refer to the installation manual provided with the model concerned.
Extension drain hose 
(Option: RB-821SW)
6 mm thick heat resisting 
polyethylene foam
For the rear left and left piping
Do not allow the drain hose 
to become slack.
Insulate the refrigerant pipes 
separately, not together.
 
250 mm or more 
from wall
In principle, 
leave open
When installing the outdoor unit, 
leave open in at least two of 
directions (A), (B), (C) and (D) 
shown in the figure below.
Ensure sufficient space 
to allow drainage
(A)
(B)
(C)
(D)
Power cord
Y
Wall
Bottom right
Rear 
right
Right
Left
Bottom 
left
Rear left
As shown in the figure, position 
power cord and connecting cable 
downward, and lead out along 
piping connection port.
Before installing the wireless remote controller
• With the remote controller 
cover removed, correctly load 
the supplied batteries while 
observing their polarity.
3   Batteries
Cover
2   Wireless remote controller
2 Wireless 
remote controller
100 mm or more 
from wall
4 Remote controller holder
7 Remote controller 
holder mounting screw
50 mm or more 
from wall
80 mm or more only 
when unobstructed to 
the front and both sides
Air filters
5 Plasma pure filter
140 mm or more
Hook
Hook
Hook
47 mm or more
74 mm 
or more
Z Shield pipe 
(for extension 
drain hose)
6 Mounting screw
200 mm 
or more
Cut the piping hole 
slightly sloped
10.  INSTALLATION PROCEDURE
10-1. Safety Cautions