Справочник Пользователя для Toshiba RAV-SM561BT-E

Скачать
Страница из 126
31
8.  INDOOR UNIT CONTROL
8-1. Indoor Control Circuit
Network adapter (Sold separatrly)
Indoor control P.C. board (MCC-1402)
CPU
EEPROM
#1
#3
A
B
Indoor unit
Main (Sub) master remote controller
Run Warning
Ready Thermo. ON
Cool Heat Fan
Outside output
Driver
Remote controller
communication circuit
CPU
H8/3039
Louver
motor
Drain
pump
Indoor
fan
motor
Transformer
Outdoor unit
1 2 3
1 2 3
DC5V
CPU
LCD
driver
Function setup
Key switch
Function setup
Key switch
Weekly timer
Secondary
battery
Power
circuit
DC5V
*
3
CN2
CN1
1 2 3
Outdoor
unit
Same as
the left
*
2
#2
A
B
A
B
1 2 3
Outdoor
unit
Same as
the left
*
2
Max. 8 units are connectable.*1
*1 Max. 7 units when network 
adapters are attached
*2 Network adapters are attached 
to only one unit.
*3 Weekly timer is not connectable 
to the sub remote controller.
Network adapter P.C. board
(MCC-1401)
Power circuit
DC5V
Sold separatrly
Sold separatrly
DC280V
X
Y
DC20V
DC12V
DC5V
Display
LCD
Display
LCD
Display
LED
Power
circuit
CPU
H8/3687
Humidifier
relay output
Heater relay
output
Switch
setup
AI NET
communication
circuit
Remote controller
communication
circuit
Remote controller
communication
circuit
TA sensor
TC sensor
TCJ sensor
Float input
Serialsend/
receive circuit
AC
synchronous
signal input
circuit
Power
circuit
CPU
TMP88CH47FG
(TMP88PH47FG)
Fan motor
control circuit
Central control remote controller
(
Sold separatrly
)