Справочник Пользователя для Toshiba RAS-16GAVP-E

Скачать
Страница из 116
– 18 –
6.  SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E
6-2. Outdoor Unit
RAS-10GAVP-E, RAS-13GAVP-E, RAS-16GAVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
Type
MF-280-30-5R
( – )
( – )
MP24Z
Specifications
DC280–340V, 30W
10k
Ω
 at 25°C
10k
Ω
 at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outside fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (6P)
Compressor
Coil for P.M.V.
Coil for 4-way valve
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-20F1
CAM-MD12TF
VHV
Rating
L = 10mH, 16A × 2
DC140V, 43W
10k
Ω
 (25°C)
62k
Ω
 (20°C)
10k
Ω
 (25°C)
10k
Ω
 (25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220–240V