Справочник Пользователя для Toshiba RAS-16GAVP-E

Скачать
Страница из 116
– 40 –
Item
16. Clean  operation
release
Operation flow and applicable data, etc.
Setting the clean operation release
Description
* J04 will be near the MCU so take
steps to ensure that it will not be
exposed to excessive levels of
heat.
Also take care to avoid solder
bridging with the surrounding
components.
Setting the clean operation
Indoor P.C. board
Add J04 of the indoor P.C. board assembly.
*  This cancels the auto restart function.
Hold down the auto operation switch on the indoor unit 
for at least 3 seconds but not more than 10 seconds.
The indoor unit’s buzzer emits three beeps, and 
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation  release setting.
Cut J04 of the indoor P.C. board
*  This step may be skipped if the auto restart function 
  is not required.
Hold down the auto operation switch on the indoor unit 
for at least 3 seconds but not more than 10 seconds.
The indoor unit’s buzzer emits three beeps, and 
the OPERATION indicator flashes at 5 Hz intervals.
This completes the clean operation setting.
J04