Справочник Пользователя для Toshiba RAS-M18EAV-E

Скачать
Страница из 136
– 53 –
Item
16. Clean
operation
release
J04 
Operation flow and applicable data, etc.
Setting the clean operation release
Add J04 of the indoor P.C. board 
assembly.
* This cancels the auto restart function.
Hold down the auto operation switch on 
the indoor unit for at least 3 seconds but 
not more than 10 seconds.
The indoor unit’s buzzer emits three 
beeps, and the OPERATION indicator 
flashes at 5 Hz intervals.
This completes the clean operation  
release setting.
* J04 will be near the 
MUC so take steps to 
ensure that it will not be 
exposed to excessive 
levels of heat.  Also 
take care to avoid 
solder bridging with the 
surrounding 
components.
Setting the clean operation
Cut J04 of the indoor P.C. board
* This step may be skipped if the auto 
restart function is not required.
Hold down the auto operation switch on 
the indoor unit for at least 3 seconds but 
not more than 10 seconds.
The indoor unit’s buzzer emits three 
beeps, and the OPERATION indicator 
flashes at 5 Hz intervals.
This completes the clean operation 
setting.
Outline diagram of P.C. board
Description