8-2. Installation Diagram of Indoor and Outdoor Units
For installation of the indoor unit, use the paper pattern on the back.
3   Clip anchor
Clip anchor
Hook
66 mm or more
Hook
1   Installation
     plate
8   Mounting screw
Hook
120 mm or more
Front cabinet
Front panel
Air filter
(Attach to the back side.)
(Attach to the back side.)
5   Shield pipe
6   Pan head 
     wood screw
4   Remote control 
     holder
2   Wireless 
     remote 
     control
9   Deodorizing 
     filter
10  Purifying 
      filter
11  
Filter
frame
100 mm or more
400 mm or more
Loop the connective cable
(about 100 mm in diameter
and 300~350 mm long).
600 mm or more
Electric parts
cover
45 mm or more
600 mm or more
2 Wireless remote control
7
Batteries
Cover
6 mm thick heat resisting
polyethylene foam
Bottom
Rear
Right
Rear left
Left
Cut the piping hole
sloped slightly
Wall
120 mm 
   or more
For the rear and left piping
Insert the remote control holder
cushion between the indoor 
unit and wall, and lift indoor 
unit to make work easier.
Do not allow the drain hose to 
get slack.
Make sure to run the drain 
hose sloped downward.
The auxiliary piping can be 
connected the left, rear left, 
rear, right or bottom.
Insulation of refrigerant pipes 
insulates the pipes separately, 
not together.
Before install the wireless 
remote control
•  With the remote control cover 
   open, load the batteries 
   supplied correctly, observing 
   their polarity.
Extension
drain hose
(Option: