Procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove E-parts cover.
(1- ST1T ø4 x 10   )
3) Remove the cord clamp (2- ST2T ø4 x 12   ) and
remove the connecting cable.
4) Remove the front cabinet. (7- ST1T ø4 x 10    with
nylon washer)
• Pull the front lower portion toward you, and remove
  it pulling out upward.
1) Remove the fixing screw securing the capacitor
band.
(1- ST2T ø4 x 8   )
2) Remove the cable connected to the terminal.
1) Remove the fixing screw.
(1- ST2T ø4 x 8   )
2) Remove the cable connected to the terminal.
1) Perform the process 

 above.
2) Remove terminal cover of compressor.
3) Remove OL holder and pull OL relay up.
4) Remove Fustons of leads.