Справочник Пользователя для Toshiba RAM-SM560UT-E

Скачать
Страница из 110
97
 CAUTION
• Bind the auxiliary pipes (two) and connecting cable with tape tightly.  In case of left-side pipe exit and rear-left
exit, bind the auxiliary pipes (two) only with facing tape.
Indoor unit
Connecting cable
Drain hose
Installation plate
Auxiliary pipes
• Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit.
• Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound
on the connecting pipe to avoid double-taping at the joint, then seal the joint with vinyl tape, etc.
• In order to reduce the possibility of condensed water being produced within the indoor unit, make sure to
insulate both the connecting pipes.
(Use a suitable form of insulation material specifically design designed for refrigeration pipe work.)
• When bending a pipe, ensure care is taken to prevent pipe damage.
Drainage
1. Run the drain hose sloped downwards.
50 mm
or more
Do not rise the drain hose.
Do not form the drain hose 
into the waved shape.
Do not put the 
drain hose end 
into water.
Do not put the drain 
hose end into the 
drainage ditch.
2. It is not possible to add water to the drain pan to
confirm correct drainage.  To do this, the unit must be
operated in the COOL mode.
3. When connecting extension drain hose, insulate the
connecting part of extension drain hose with pipe
insulation.
Pipe insulation
Extension drain hose
Inside the room
Drain hose
 CAUTION
Arrange the drain pipe to allow proper drainage from the unit.  Incorrect drainage can result in condensation
problems.
This structure of this air conditioner is designed
condensed water, which may form on the back of the
indoor unit, into the drain pan.
Therefore, do not store the power cables and other parts
within the drain guide.
Space for 
pipes
Wall
Drain 
guide
5
DRAIN PIPING WORK