Справочник Пользователя для Toshiba RAS-10SAVP-E

Скачать
Страница из 119
– 22 –
6.  SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E
RAS-10SKVP-ND, RAS-13SKVP-ND, RAS-16SKVP-ND
6-2. Outdoor Unit
RAS-10SAVP-E, RAS-13SAVP-E, RAS-16SAVP-E
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
No.
1
2
3
4
5
Parts name
Fan motor (for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Heat exchanger temp. sensor (TCJ-sensor)
Louver motor
Type
MF-280-30-5R
( – )
( – )
( – )
MP24Z3N
Specifications
DC280–340V, 30W
10k
Ω
 at 25°C
10k
Ω
 at 25°C
10k
Ω
 at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
9
10
11
12
Parts name
Reactor
Outside fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (6P)
Compressor
Coil for P.M.V.
Coil for 4-way valve
Cord heater assembly (-ND model only)
Heater fuse assembly (-ND model only)
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-24F
CAM-MD12TF
STF
CSC-2
——
Rating
L = 10mH, 16A
DC140V, 43W
10k
Ω
 (25°C)
62k
Ω
 (20°C)
10k
Ω
 (25°C)
10k
Ω
 (25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220–240V
AC230V, 75W
AC250V, 3.15A