Справочник Пользователя для Goodman Mfg GPH15M

Скачать
Страница из 40
p
rodUCt
 s
peCifiCations
p
rodUCt
 s
peCifiCations
28 www.goodmanmfg.com 
SS-GPH15M
a
irflow
 d
ata
Model
Motor  
Tap Speed
Volts
E.S.P (In. of H
2
O)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
GPH15 
24M41A*
T1 (G)
230
CFM
882
808
727
649
545
---
---
---
Watts
82
86
92
102
108
---
---
---
T2 / T3 (W2)
230
CFM
933
873
810
733
637
584
---
---
Watts
93
103
109
120
126
135
---
---
T4 / T5 (Y)
230
CFM
1058
1012
945
896
816
723
672
---
Watts
124
136
142
153
168
172
179
---
GPH15 
30M41A*
T1 (G)
230
CFM
893
824
752
665
575
---
---
---
Watts
87
95
101
111
115
---
---
---
T2 / T3 (W2)
230
CFM
1132
1070
1011
959
889
827
733
669
Watts
153
162
168
179
184
195
206
208
T4 / T5 (Y)
230
CFM
1287
1236
1165
1123
1066
1012
958
857
Watts
211
217
228
239
244
255
265
272
GPH15 
36M41A*
T1 (G)
230
CFM
852
764
711
592
545
-
-
-
Watts
80
82
86
95
99
-
-
-
T2 / T3 (W2)
230
CFM
1232
1190
1131
1082
1023
966
889
819
Watts
202
214
221
229
235
246
258
264
T4 / T5 (Y)
230
CFM
1267
1213
1162
1120
1058
1009
932
841
Watts
218
226
236
245
247
260
272
275
GPH15 
42M41A*
T1 (G)
230
CFM
893
830
741
619
557
---
---
---
Watts
89
99
104
117
131
---
---
---
T2 / T3 (W2)
230
CFM
1393
1339
1297
1230
1180
1116
1056
901
Watts
271
280
292
300
310
320
324
329
T4 / T5 (Y)
230
CFM
1511
1464
1422
1355
1313
1184
1064
983
Watts
345
354
364
381
390
392
375
360
G = Fan only 
W2 = Heat mode 
 
Y = Cooling mode
Notes
•  Data shown is dry coil. Wet coil pressure drop is approximately 0.1" H2O, for two-row indoor coil; 0.2” H2O, for three-row indoor coil; and 0.3” H2O, for 
four-row indoor coil.
•  Data shown does not include filter pressure drop, approx. 0.08” H2O.
•  ALL MODELS SHOULD RUN NO LESS THAN 350 CFM/TON. USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM. See Repair Parts list.
•  Reduce airflow by 2% for 208-volt operation.