Справочник Пользователя для Graco 24R200

Скачать
Страница из 28
Maintenance
332511A
15
Maintenance
Platen Maintenance
If the platen does not come out of the pail easily when 
the pump is being raised, the air assist tube or check 
valve may be plugged. A plugged valve prevents air from 
reaching the underside of the plate to assist in raising it 
from the pail. 
1.
Turn off main disconnect at the machine.
2.
Allow equipment to cool.
3.
Relieve pressure and disassemble air assist valve. 
Refer to Supply Systems Repair-Parts manual.
4.
Clear air assist tube in platen. Clean all parts of 
valve and reassemble. Refer to Supply Systems 
Repair-Parts manual.
5.
Remove bleed stick from platen. Push bleed stick 
through bleed relieve port (P) to remove material 
residue. See F
IG
. 3.
6.
Remove platen covers. See F
IG
. 3.
a.
Remove platen cover fasteners (F).
b.
Remove both platen covers (C) and ground wire 
from platen.
7.
Remove any excess fluid. Use a soft wire brush on 
heater coils (H). See F
IG
. 3.
8.
Inspect platen heater blocks (B) or heater (H) for 
burn or melt spots. Replace platen heater if neces-
sary. See F
IG
. 3.
9.
Check for loose connections and damaged wires.
10. Follow steps in reverse order to reassemble platen. 
NOTE: Torque platen cover fasteners (F) to 60 +/- 10 
in-lbs (6.8 +/- 1.1 N•m) for 55 gallon platen.
Remove and Reinstall Platen Wipers
Refer to Supply Units Repair-Parts manual for instruc-
tions.
F
IG
. 3: Remove Platen Covers and Heaters
F
Bleed
Stick
C
H
B
P