TZ-3 TOTALZONE® ZONE CONTROL PANEL
68-0223-2
4
INSTALLATION
Mounting
CAUTION
Equipment Damage Hazard.   
Do not mount TZ-3 inside HVAC equipment
Mount only on wall or on cold air return
1.
Mount the thermostats in each zone of the living space 
using the installation instructions provided with each 
thermostat.
2.
Mount the dampers in the ductwork using the installa-
tion instructions provided with each damper.
3.
Mount the TZ-3 zone panel near the HVAC equipment; 
locate it on a wall or on the cold-air return. See Fig. 2.
4.
Level the TZ-3 for appearance only.
Wiring
CAUTION
Voltage Hazard. 
Can cause electrical shock or equipment damage.
Disconnect power before continuing installation.
Wiring must comply with applicable codes, ordinances, and 
regulations.
1.
Connect thermostats as shown in Fig. 3-5. 
2.
Connect dampers as shown in Fig. 6-10.
3.
Connect the Discharge Air Temperature Sensor (not 
supplied) to the TL terminals.The wires are not polar-
ized. See Fig.12.
4.
Connect Add-A-Zone panels (if used) to the AZ1 and 
AZ2 terminals. The AZ1 terminal on the TZ-3 must be 
wired to the AZ1 terminal on the TAZ panel. Similarly, 
the AZ2 terminal must be wired on the TZ-3 to the AZ2 
on the TAZ.  See Fig. 13.
5.
Connect the HVAC equipment to the EQUIP terminals 
on the panel.  See Fig. 14-17.
6.
Connect a 40 VA, 24 volt transformer to TR1 (hot) and 
TR2 (common). This must be a dedicated transformer 
and any additional TAZ boards also each require a 
transformer. See Fig. 11.
Fig. 2. TZ-3 mounting location.
Wiring Diagrams (Fig. 3-17)
Conventional Thermostats
The C (common) terminal is used only on thermostats that 
require a common (for example:T8601). See Fig. 3. Wire the 
W2 terminal on a multi-stage thermostat (for example: T8624) 
to the W2 on the panel for second stage control from the 
thermostat. If the thermostat has a Y2 terminal, do not 
connect it to the panel.
Fig. 3. Typical single-stage thermostat wiring.
Heat Pump Thermostats
Select a heat pump thermostat from Table 1. If the thermostat 
selected has a separate Y1 and W1, see Fig. 4. When using 
the thermostat to control the second stage of heat (W2), set 
DIP switch 5 to On, and DIP switch 1 to Off. Set both DIP 
switches 6 and 7  to Off. 
M19063
WATER 
HEATER
T2-3
EL
EC
TR
ON
IC A
IR C
LE
AN
ER
RETURN
AIR
T2-3
OPTIONAL
LOCATION
FURNACE 
OR BOILER
HIGH
 EFFICIENCY
AIR CLEANER
L
W2
G
Y
R
W
M6
G
Y
R
W
C
M4
M1
THERMOSTAT
ZONE CONNECTIONS ON PANEL
ZONE THERMOSTAT
M19064
MOTOR