RECOMMENDED TUBE  DIAMETERS
 
*  For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.
 
CHECK-FLO-RATER®
 
*  Piston listed is for any approved non-capillary tube coil combination. 
Piston is shipped with outdoor unit and must be installed in an approved 
indoor coil.
 
SOUND POWER (dBA)
 
 
 
LIQUID TUBE DIAMETER (IN.)
VAPOR TUBE DIAMETER (IN.)
UNIT
SIZE
0 to 50 Ft
Tube Length
Long-Line Applications*
0 to 50 Ft
Tube Length
Long-Line Applications*
(Maximum Diameter)
 
018, 024
3/8
3/8
5/8
3/4
030, 036
3/4
7/8
042, 048
7/8
1-1/8
060
1-1/8
1-1/8
 
UNIT SIZE-SERIES
PISTON*
IDENTIFICATION NO.
 
018, E
55
024, E
59
030, E
67
036, E
73
042, E
78
048, E,F
84
060, E
93
 
UNIT
SIZE
SOUND
LEVEL (dBA)
OCTAVE BAND CENTER FREQUENCY (Hz)
125
250
500
1000
2000
4000
8000
 
018
72
54.5
63.0
65.5
66.0
63.5
59.0
51.5
024
74
51.5
61.0
62.5
65.5
62.0
58.5
52.5
030
74
57.0
64.0
67.0
69.0
64.0
60.0
52.5
036
76
59.0
66.0
67.0
69.5
66.5
62.5
56.0
042
76
58.0
65.0
67.5
69.0
65.5
61.0
54.0
048
78
60.0
64.0
68.5
68.5
67.5
64.5
59.5
060
78
61.5
64.5
69.0
70.0
68.0
66.0
60.5
   
M
A
N
U
F
A
C
T
U
R
E
R
CE
RT
IFIED
TO ARI
AS
C
O
M
P
L
Y
IN
G
W
IT
H
A
RI
STANDARD
21
0
U
N
IT
A
R
Y
AIR
CO
N
D
IT
IO
N
IN
G
EQUIPMENT
 
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI
REGISTERED QUALITY SYSTEM