Manual 2100-581B 
Page  4 of 26
WALL MOUNT GENERAL INFORMATION
AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE
 
W  
42  
A   2  – 
A  
10 
A
 
NOTE:  Vent options X, B and M are without exhaust capability.  May require separate field supplied barometric relief in building.
SHIPPING DAMAGE
Upon receipt of equipment, the carton should be 
checked for external signs of shipping damage.  If 
damage is found, the receiving party must contact 
the last carrier immediately, preferably in writing, 
requesting inspection by the carrier’s agent.
GENERAL
The equipment covered in this manual is to be installed 
by trained, experienced service and installation 
technicians.
The refrigerant system is completely assembled and 
charged.  All internal wiring is complete.
The unit is designed for use with or without duct work.  
Flanges are provided for attaching the supply and return 
ducts.
These instructions explain the recommended method 
to install the air cooled self-contained unit and the 
electrical wiring connections to the unit.
These instructions and any instructions packaged with 
any separate equipment required to make up the entire 
air conditioning system should be carefully read before 
beginning the installation.  Note particularly “Starting 
Procedure” and any tags and/or labels attached to the 
equipment.
While these instructions are intended as a general 
recommended guide, they do not supersede any 
national and/or local codes in any way.  Authorities 
having jurisdiction should be consulted before the 
installation is made.  See Page 3 for information on 
codes and standards.
Size of unit for a proposed installation should be based 
on heat loss calculation made according to methods 
of Air Conditioning Contractors of America (ACCA).  
The air duct should be installed in accordance with the 
Standards of the National Fire Protection Association 
for the Installation of Air Conditioning and Ventilating 
Systems of Other Than Residence Type, NFPA No. 
90A, and Residence Type Warm Air Heating and Air 
Conditioning Systems, NFPA No. 90B.  Where local 
regulations are at a variance with instructions, installer 
should adhere to local codes.
KW
MODEL NUMBER
CONTROL MODULES
(See Spec. Sheet S3397)
VOLTS & PHASE
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
REVISIONS
VENTILATION OPTIONS
X  -  Barometric Fresh Air Damper (Standard)
B  -  Blank-off Plate
M -  Motorized Fresh Air Damper
V  -  Commercial Ventilator - Motorized with Exhaust
R  -  Energy Recovery Ventilator - Motorized with Exhaust
    (See Spec. Sheet S3397)
S  -  Economizer - School Versions, Enthalpy
W -  Economizer - Equipment Building, Enthalpy
T  -  Economizer - Equipment Building, DB Temp.
FILTER OPTIONS
X  - One Inch Throwaway (Standard)
W - One Inch Washable
P  - Two Inch Pleated
COLOR OPTIONS
X  -  Beige (Standard)
1 - White
4  -  Buckeye Gray
5  -  Desert Brown
6  -  Dark Bronze
A - Aluminum
S  -  Stainless Steel
COIL OPTIONS
X - Standard
1  -  Phenolic Coated Evaporator
2  -  Phenolic Coated Condenser
3  -  Phenolic Coated Evaporator  
    and Condenser
OUTLET OPTIONS
X  - Front (Standard)
T - Top Outlet (W30A, W36A Only)
CAPACITY
17 - 1½ Ton
18 - 1½ Ton
24  -  2 Ton
30 - 2½ Ton
36  -  3 Ton
42 - 3½ Ton
48  -  4 Ton
60  -  5 Ton
70  -  6 Ton
A  -  Right Hand Air Conditioner
L  -  Left Hand Air Conditioner