16
Majestic Fireplaces
®
 NVB Series B-Vent
7412950
Troubleshooting
FP396
Gas Supply On
• Supply Line Hooked up
• Shutoff Valve Open
NO
NO
NO
NO
• Lockout has engaged. Wait 60
   seconds and try again.
• Piezo not tight enough for good
   ground.
• For spark at electrode while 
   depressing Piezo (Red Button)
   1/8" gap to pilot hood needed.
• All wiring connections
• Replace Piezo Ignitor
• Thermodisk
• For Air in the lines
• Thermopile needs a minimum
   325mV. Adjust pilot flame height.
• All wiring connections
• Replace Thermopile
• Thermocouple needs a minimum
   of 14mV.
• Defective valve. Turn to pilot, 
   meter should read greater than
   100mV.
• Thermodisk
Pilot Lights with
Piezo Ignitor
YES
YES
YES
YES
Pilot Stays Lit
Pilot Lights Main
Burner
System OK
START
CHECK
•  Wall switch is not turned on. 
   Watch for grounded wires!
• Thermopile needs a minimum
   325mV
• Plugged burner orifice
Nova SIT 820 Standing Pilot