Справочник Пользователя для Majestic Appliances NVBC42

Скачать
Страница из 24
11
Majestic Fireplaces
®
 NVB Series B-Vent
7412950
FP567
Fig. 13 Venting configurations.
Venting Runs 
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
 8    9   10
1    2    3    4     5     6    7
Horizontal Run (in feet)
Ve
rtical Run (in feet)
A
A: Vertical installations up to 40 feet (12m) in 
     height. Up to a 6 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 90-degree elbows or four 
     45-degree elbows.
B: Vertical installations up to 40 feet (12m) in 
     height. Up to a 10 ft. horizontal vent run can be
     installed within the vent system using a 
     maximum of two 45-degree elbows. 
B
= Acceptable venting configuration
= Unacceptable venting configuration
FP567a
Fig. 14  Venting configurations when installing 36GSKBB.
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
2
4
6
8
10 12 14 16 18
20
A
Horizontal Run (in feet)
V
ertical Run (in feet)
= Acceptable venting configuration
= Unacceptable venting configuration
A: Vertical installation up to 40 feet (12m) in
    height. Up to a 16 ft. horizontal vent run
    can be installed within the vent system
    using a maximum of two 90 degree elbows 
    or four 45 degree elbows.
B: Vertical installation up to 40 feet (12m) in
    height. Up to a 20 ft. horizontal vent run 
    can be installed within the vent system
    using a maximum of two 45 degree elbows.
B