ALTERNATE  FLOOR  PROTECTION
All  floor  protection  materials  must  be  non-combustible  ie.  metal,
brick,  stone,  mineral  fiber  boards).    Any  combustible  material
may not be used.
The  easiest  means  of  determining  if  a  proposed  alternate  floor
material  meets  requirements  listed  in  this  manual  is  to  follow  this
procedure.
R-value  =  thermal  resistance
k-value  =  thermal  conductivity
C-value  =  thermal  conductance
1.    Convert  the  specification  to  R-value;
a.  If  R-value  is  given,  no  conversion  is
needed.
b. If k-value is given with a required
thickness  (T)  in  inches:  R=1/k  X T.
c. If C-value is given: R=1/C.
2.    Determine  the  R-value  of  the  proposed  alternate
          floor  protector.
a.  Use  the  formula  in  Step  1  to  convert
values  not  expressed  as  “R”.
b. For multiple layers, add R-values of each
layer  to  determine  overall  R-value.
3.    If  the  overall  R-value  of  the  sustem  is  greater
          than  the  R-value  of  the  specified  floor  protector,
     the alternate is acceptable.
EXAMPLE:
The  specified  floor  protector  should  be  3/4”  thick  material  with  a
k-factor  of  0.84.    The  proposed  alternate  is  4”  brick  with  a  C-
factor  of  1.25  over
1/8”  mineral  board  witha  k-factor  of  0.29.
Step  A.    Use  formula  above  to  convert  specifications  to  R-value.
R=1/k X T= 1/.84 X .75 = .893
Step B.  Calculate R of proposed system.
4”  brick  of  C-1.25,  therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8”  mineral  board  of  k  =  0.29  therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8  +  0.431=1.231
Step C.  Compare proposed system R = 1.231 to specified R of
0.893.    Since  R  is  greater than required,  the  system  is  acceptable.
Definitions:
Thermal  conductance  =
C =        Btu        =           W
                      (hr)(ft
2
)(F)          (m
2
)(K)
Thermal  conductivity  =
            
k =
     Btu        =           W        =     (Btu)
                  (hr)(ft
2
)(F)          (m
2
)(K)       (hr)(ft)(F)
Thermal  resistance  =
R = 
     Btu        =       (m
2
)(K)      =     (Btu)(inch)
                     (hr)(ft
2
)(F)               W                  (hr)(ft
2
)(F)
FOR  THE  JØTUL  OSLO  F500    WOOD  STOVE  REQUIRES
FLOOR  PROTECTION  WITH A  MINIMUM  INSULATING  R
VALUE  OF 0.5.
ALCOVE INSTALLATION REQUIRE A MINIMUM R VALUE
OF 1.6. (IF A UL/ULC or WHI LISTED HEARTH PAD IS NOT
USED.)
APPENDIX A:
19
PARTS LIST FOR THE OSLO F500
1
ash door
2
ash lip
3
front door
4
front
5
right side
6
left side
7
side door
8
rear plate
9
top
10
top cover
11
bottom
12
leg
13
smoke outlet
14
ash  house
15
ashpan
16
inner bottom
17
firegrate
18
refractory brick
19
air manifold
20
tube frame holder
21
bottom left tube holder
22
upper left tube holder
23
front tube
23
middle tube
24
rear tube
25
bottom right tube holder
26
upper right tube holder
27
top burn plate
28
insulating blanket (top)
*
gasketing for top
*
gasketing for top cover
29
side burn plates 2 pcs
*
insulating blanket for sides
30
door glass
*
glass  gasketing
*
glass clips
31
inner front
32
primary air lever
33
air valve/slider
34
inspection cover
optional equipment
40
bottom heatshield
41
rear heatshield
42
top exit shield