Справочник Пользователя для Hotpoint GC751TX

Скачать
Страница из 12
6
GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
1.  Remove the hob grids and slide the burners off their seats.
2.  Unscrew the nozzles using a 7 mm socket spanner, and replace them 
with nozzles for the new type of gas (see table 1 “Burner and nozzle 
characteristics”).
3.  Reassemble the parts following the above procedure in the reverse order.
4.  Once this procedure is finished, replace the old rating sticker with one 
indicating the new type of gas used. Sticker are available from any of our 
Service Centres.
replacing the triple ring burner nozzles
1.  Remove the pan supports and lift the burners out of their housing. The 
burner consists of two separate parts (see pictures).
2.  Unscrew the nozzles using a 7 mm socket spanner. Replace the nozzles 
with models that are configured for use with the new type of gas (see Table 
1). The two nozzles have the same hole diameter.
3.  Replace all the components by completing the above operations in reverse 
order.
•  Adjusting the burners’ primary air
Does not require adjusting.
•  Setting the burners to minimum
1.  Turn the tap to the low flame position;
2.  Remove the knob and adjust the adjustment screw, which is positioned 
in or next to the tap pin, until the flame is small but steady.
3.  Having adjusted the flame to the required low setting, while the burner is 
alight, quickly change the position of the knob from minimum to maximum 
and vice versa several times, checking that the flame does not go out.
4.  Some appliances have a safety device (thermocouple) fitted. If the device 
fails to work when the burners are set to the low flame setting, increase 
this low flame setting using the adjusting screw.
5.  Once the adjustment has been made, replace the seals on the by-passes 
using sealing wax or a similar substance.
! If the appliance is connected to liquid gas, the regulation screw must be 
fastened as tightly as possible.
! Once this procedure is finished, replace the old rating sticker with one 
indicating the new type of gas used. Stickers are available from any of our 
Service Centres.
! Should the gas pressure used be different (or vary slightly) from the 
recommended pressure, a suitable pressure regulator must be fitted to the 
inlet pipe (in order to comply with current national regulations).
Electrical 
connections
DATA PLATE
see data plate
This appliance conforms to the following 
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low 
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04 
(Electromagnetic Compatibility) and 
subsequent amendments
- 93/68/EEC dated 22/07/93 and 
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and 
subsequent amendments.
- 2012/19/EC and subsequent 
amendments.