14
U37-1 Regency
®
 ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove
Flex Liner
Exhaust
Flue
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563
Co-linear DV
Vertical Termination
Cap # 946-529
Inner Pipe
Adapter
with Kit#
946-563
U37 Rigid Pipe
Adaptor
Part # 640-994
Outer
Pipe
with Kit#
946-563
o
Check local
codes whether
a continuous
length is re-
quired or if
certified joiner
kits may
be used.
#948-305
(35 ft)
VERTICAL TERMINATION WITH 
CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING 
A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Ar-
rangements chart in the "Rigid Pipe Venting - Vertical Terminations" section for minimum and maximum fl ue lengths.See chart  below for minimum 
distances from roof. Periodically check that the vent is unrestricted.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, keep the fl exible liner as straight as possible
avoid unnecessary bending.
The Air Intake pipe must  be attached to the inlet air collar of the termination cap.
Required Parts:
Part # 
Description
946-529 Co-linear 
DV 
Vertical 
Termination 
Cap
948-305 
3" Flex - 35 ft.
640-994 U37 
Rigid 
Pipe 
Adaptor
946-563 
Co-Axial to Co-Linear Adapter Kit
 
which contains the following: 
 Co-linear 
Flex 
Adapter 
(270-585) 
 Outer 
Pipe 
(946-257)
 Inner 
Pipe 
Adapter 
(946-219)
Alternate Approved Caps
980 Vertical 
Termination 
Cap
991 High 
Wind 
Cap
923GK 3" 
Co-linear 
Adapter 
 with 
fl 
ashing