Справочник Пользователя для Quadra-Fire CASTILE-PMH

Скачать
Страница из 44
RR
R
October 11,, 2005
250-6422D
Page  17
Castile Pellet Stove 
7
Appliance Set-Up
A. Outside Air Kit Instructions 
Flex Hose
Hose Clamp
Collar Assembly
Trim Ring
Termination
Cap Assembly
Hose Clamp
Parts Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 
2 hose clamps, 1 collar assembly,1 termination cap assem-
bly, 1 trim ring, 12 screws. 
1.  Measure distance from floor to air vent opening in appli-
ance and mark location on wall.  
Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch 
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch 
(76-89mm) opening on outside of house.
2.  Use hose clamp to secure flex pipe to collar assembly.
3.  Slide trim ring over flex pipe and run pipe through wall.
4.  Attach  hose  to  outside  termination  cap  with  second 
hose clamp.
5.  Secure termination cap to outside surface.
6.  Secure trim ring to interior wall.
Tools Needed: Phillips headscrewdriver; wire cutters; hole 
saw or jig saw.
CAUTION
Never draw outside combustion air from:
•  Wall, floor or ceiling cavity
•  Enclosed space such as an attic or garage
Mounting Slots
Pre-cut Hole
Align hooks with slots, push up
and slide forward
1. 
Figure 17.1 shows bottom of convection blower mount 
and  pre-cut  air  vent  opening  for  reference  only.    Air 
channel should be mounted with stove in upright posi-
Figure 17.1
3.   Secure  air  channel  to  appliance  with  2  screws  and  
secure  the  collar  assembly  to  the  air  channel  with  2 
screws.  
Figure 17.3.
2.  Align  hooks  in  air  channel  with  slots  in  convection 
blower mount and ash box, 
Figure 17.2.  Push up and 
slide forward. 
Attach air channel to stove with 2 screws
Attach collar to air channel with 2 screws
Figure 17.2
Figure 17.3
Figure 17.4