Castile Pellet Stove 
2
Getting Started
A.  Design, Installation & Location 
Considerations
1. Appliance Location
Consideration must be given to safety, convenience, traffic 
flow, and the fact that the appliance will need a chimney and 
chimney connector.  It is a good idea to plan your installation 
on  paper,  using  exact  measurements  for  clearances  and 
floor protection, before actually beginning the installation.  If 
you are not using an existing chimney, place the appliance 
where there will be a clear passage for a factory-built listed 
chimney through the ceiling and roof.  
Check  with  your  local  building  code  agency  before  you 
begin your installation.  Be sure local building codes do not 
supersede  UL  specifications  and  always  obtain  a  building 
permit  so  that  insurance  protection  benefits  cannot  be 
unexpectedly cancelled.  If any assistance is required during 
installation, please contact your local dealer.
We recommend that a qualified building inspector and your 
insurance company representative review your plans before 
and after installation.
2. Thermostat Location
The  thermostat’s  location  will  have  some  effect  on  the 
appliance’s operation.  When the thermostat is located close 
to the appliance, it may require a slightly higher temperature 
setting  to  keep  the  rest  of  the  house  comfortable.    If  the 
thermostat location is in an adjacent room or on a different 
floor  level,  you  will  notice  higher  temperatures  near  the 
appliance.
B. Fire Safety
Maintain  the  designated  clearances  to  combustibles.  
Insulation must not touch the chimney.  You must maintain 
the  designated  air  space  clearance  around  the  chimney.  
This  space  around  a  chimney  is  necessary  to  allow 
natural  heat  removal  from  the  area.    Insulation  in  this 
space  will  cause  a  heat  buildup,  which  may  ignite  wood 
framing.  
NOTE:  Clearances may only be reduced by 
means  approved  by  the  regulatory  authority  having 
jurisdiction.
To provide reasonable fire safety, the following should be 
given serious consideration:
1.  Install  at  least  one  smoke  detector  on  each  floor  of 
your  home  to  ensure  your  safety.   They  should  be 
located  away  from  the  heating  appliance  and  close 
to  the  sleeping  areas.    Follow  the  smoke  detector 
manufacturer’s placement and installation instructions, 
and be sure to maintain regularly.  
2.  A  conveniently  located  Class A  fire  extinguisher 
to  contend  with  small  fires  resulting  from  burning 
embers.
3.  A  practiced  evacuation  plan,  consisting  of  at  least 
2 escape routes.
4.  A plan to deal with a hopper fire as follows:
 
In the event of a hopper fire:
A.  Notify fire department
B.  Prepare occupants for immediate evacuation.
C.  Close all openings into the appliance.
D.  While awaiting fire department, watch for ignition 
of  adjacent  combustibles  from  overheated  vent 
pipe, hot embers or sparks from the chimney.
E.  Pour  a  bucket  of  water  into  the  appliance 
hopper.
CAUTION
•  Do NOT connect this unit to a chimney flue servicing 
another appliance.
•  Do NOT connect to any air distributon duct or system.
Fire Hazard.
WARNING
•  Do not operate appliance before reading 
and understanding operating instructions.
•  Failure to operate appliance properly may 
cause a house fire.
Installation and service of this appliance should be 
performed by qualified personnel. Hearth & Home 
Technologies recommends NFI certified profession-
als, or technicians supervised by an 
NFI certified professional.