3
Appliance Location and Clearances
A. Selecting Appliance Location
NOTE: 
·  
Illustrations refl ect typical installations and are FOR  
DESIGN PURPOSES ONLY.
·
    Illustrations/diagrams are not drawn to scale.
·
   Actual installation may vary due to individual design    
preference.
When selecting a location for your appliance it is important to 
consider the required clearances to walls (see 
Figure 3.1).  
Figure 3.1   
WARNING
Fire Risk
Provide adequate clearance:
•  Around air openings
• To 
combustibles
•  For service access
Locate appliance away from traffi c areas.
Fire Risk.
  Locate and install appliance to all 
clearance specifi cations in manual.
WARNING
B. Clearances to Combustibles 
Model
A
B
C
D
E
F
Sapphire Gas Stove
Inches 
6
6
3
54
36
34
Millimeters
152
152
76
1372
914
1016
NOTE:  For actual appliance dimensions refer to 
Section 12.
NOTE: Flooring beneath appliance may reach 90 degrees 
plus room ambient temperature. Check with flooring 
manufacturer for maximum temperature allowed on flooring 
surfaces.
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the 
appliance causing discoloration or odor.
Fire Risk. 
Odor Risk.
Tipping Risk
•  Install appliance on a stable, level platform/
fl oor strong enough to support appliance 
without tipping. 
• USE 
wood 
fl ooring, ceramic tile, brick hearth 
or high pressure laminate fl ooring applied 
directly over the sub-fl ooring material.