3100 Wood Stove Series (ACC)
Figure 20.1
SparkArestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Double wall
connector pipe
Floor Protector
Outside Air Floor Vent
OutsideAir
Rear Vent
CAUTION
Maintain structural integrity of mobile home:
•   Floor, wall, ceiling and/or roof.
Do NOT cut through:
•  Floor joist, wall, studs or ceiling trusses.
•  Any supporting material that would affect the structural 
integrity.
• 
Never install in a sleeping room.
Consumes oxygen in the room.
WARNING
Asphyxiation Risk.
6
Mobile Home Installation
10.  Burn wood only.  Other types of fuels may generate 
poisonous gases (e.g., carbon monoxide).
11.  If unit burns poorly while an exhaust blower is on in 
home, (i.e., range hood), increase combustion air.
12.  Installation shall be in accordance with the Manufacturers 
Home & Safety Standard (HUD) CFR 3280, Part 24.
1.  An outside air inlet must be provided for combustion   See 
page 14 for installation information.
2.  Appliance must be secured to the mobile home structure 
by bolting the pedestal through hearth pad and into 
fl oor.  
3.  Appliance must be grounded with #8 solid copper 
grounding wire or equivalent and terminated at each end 
with N.E.C. approved grounding device.
4.  Appliance must be installed with an approved UL103 HT 
ventilated chimney connector, UL103 HT chimney, and 
terminal cap with spark arrestor.  Never use a single wall 
connector (stove pipe) in a mobile home installation.  Use 
only double-wall connector pipe, Dura-Vent DVL, Selkirk 
metalbestos DS or Security DL double-wall connector or 
any listed double-wall connector pipe.
5.  In Canada, this appliance must be connected to a 6 inch 
(152mm) factory-built chimney conforming to CAN/ULC-
629M, STANDARD FOR FACTORY BUILT CHIMNEYS. 
6.  Follow the chimney and chimney connector manufacturer’s 
instructions when installing the fl ue system for use in a 
mobile home.
7.  Maintain clearance to combustibles.
8. Floor protection requirements must be followed 
precisely.
9.  Use silicone to create an effective vapor barrier at the 
location where the chimney or other component penetrates 
to the exterior of the structure.
NOTE:  Offsets from the vertical, not exceeding 45°, are 
allowed per Section 905(a) of the Uniform Mechanical Code 
(UMC). Offsets greater than 45° are considered horizontal 
and are also allowed, providing the horizontal run does not 
exceed 75% of the vertical height of the vent. Construction, 
clearance and termination must be in compliance with the 
UMC Table 9C. This installation must also comply with NFPA 
211.
NOTE: Top sections of chimney must be removable to allow 
maximum clearance of 13.5 feet (411cm) from ground level 
for transportation purposes.
You must use a Quadra-Fire Outside Air Kit Part 
OAK-ACC and (depending on fl oor installation, 
Part SRV7033-041) for installation in a mobile 
home.