Mt. Vernon Pellet Insert (AE)
E.  Chimney and Exhaust Connection
1. 
Chimney  &  Connector:    Use  3  or  4  inch  (76-102mm)  
diameter type "L" or "PL" venting system.  It can be vented 
vertically or horizontally.
2.  Mobile Home: Approved for all Listed pellet vent.  If using 
the 3 inch (76mm) vertical Top Vent Adapter Kit or the 3 
to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed 
double wall fl ue connector.  A Quadra-Fire Outside Air Kit 
must be used with manufactured home installations.
3.  Residential:  The 3 inch (76mm) vertical Top Vent Adapter 
Kit and the 3 to 6 inch (76-152mm) Top Vent Offset Adapter 
are tested to use 24 gauge single wall fl ue connector or 
Listed double wall fl ue connector to Class A Listed metal 
chimneys,  or  masonry  chimneys  meeting  International 
Residential Code standards for solid fuel appliances.
4.  INSTALL  VENT  AT  CLEARANCES  SPECIFIED  BY  THE 
VENT MANUFACTURER.
5
.  Secure exhaust venting system to the appliance with at 
least 3 screws.  Also secure all connector pipe joints with 
at least 3 screws through each joint.
6.  DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST 
VENTING SYSTEM OF THIS UNIT.
7.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 
SERVING ANOTHER APPLIANCE.
NOTE:   All  pipe  must  be  welded  seam  pipe  whenever 
possible.  Seal pipe joints with high temperature silicone 
(500°F [260°C] minimum rated only).
NOTE:    If  burning  shelled  field  corn,  you  must  use 
approved venting specifi cally designed for corn.  Follow 
the instructions from the venting manufacturer.
The table below can help you calculate the equivalent feet 
of pipe which is a method used to determine pellet vent size.  
Figure 15.1.
F.  Equivalent Feet of Pipe
2 ft.
2 ft.
3 ft.
2 ft.
Example of 3 Elbow-Rear Vent Termination Calculation
Figure 15.1
Pellet Venting 
Component
# of 
Elbows
Feet of 
Pipe
Multiplied 
By
Equivalent 
Feet
Components
Equivalent Feet
90
o
 Elbow or Tee
3
X
5
15
45
o
 Elbow
X
3
Horizontal Pipe
7
X
1
7
Vertical Pipe
2
X
0.5
1
Total Equivalent Feet
23
Note:  This is a generic example and is not 
intended to represent any specifi c fuel type.
•  Only LISTED venting components may be used.
•  NO OTHER vent components may be used.
•  Substitute or damaged vent components may impair 
safe operation.
WARNING! RISK OF FIRE!
WARNING! RISK OF INJURY OR PROPERTY 
DAMAGE!
•  Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. 
•  Refer to the owner’s information manual provided with this 
appliance. 
•  For assistance or additional information consult a qualifi ed 
installer, service agency or your dealer.
Vent surfaces get HOT, can cause burns 
if touched.  Non-combustible shielding or 
guards may be required.
WARNING