Справочник Пользователя для Quadra-Fire MTVERNINSAE-MBK
R
November 22, 2011
7036-135G
Page 35
Mt. Vernon Pellet Insert (AE)
10
Maintaining & Servicing Your Appliance
CAUTION! SHOCK AND SMOKE HAZARD!
• Proper Shutdown Procedure must be followed.
• Smoke spillage into room can occur if appliance is not
cool before unplugging appliance.
• Risk of shock if appliance is not turned off before servic-
ing appliance.
A. Proper Shutdown Procedure
1. Set wall control to OFF on AUTOMATIC / MANUAL SET-
TING screen. Figure 35.1.
2. Wall control screen will scroll through the following mes-
sages after setting to OFF.
• Shutdown
• Auto-Clean
Before Servicing Your Appliance
Manual
Off
Automatic
Figure 35.1
B. Quick Reference Maintenance Chart
NOTICE: These are recommendations. Clean more frequently if you encounter heavy
build-up of ash at the recommended interval or you see soot coming from the
vent. Not properly cleaning your appliance on a regular basis will void your
warranty.
vent. Not properly cleaning your appliance on a regular basis will void your
warranty.
• Off
3. Smoke spillage into the room can occur if the appliance
is not cool before unplugging.
4. There is a risk of shock if the appliance is not unplugged
before servicing the appliance.
After servicing, restart with the AUTO/MANUAL SETTINGS
screen. Figure 35.1.
screen. Figure 35.1.
Follow the detailed instructions found in this
section for each step listed in the chart below.
section for each step listed in the chart below.
Cleaning or Inspection
Frequency
Daily Weekly Every 2
Weeks
Monthly
Yearly
Ash Pan - Burning Wood Pellets
Every 5 bags of fuel
OR
X
Ash Pan - Burning Alternate Fuels
Every 1 bag of fuel
OR
X
Ash Removal from Firebox
More frequently depending on the
fuel type or ash build-up
fuel type or ash build-up
OR
X
Auto-Clean Inspection
More frequently depending on the
fuel type
fuel type
OR
X
Blower, Combustion (Exhaust)
More frequently depending on the
fuel type
fuel type
OR
X
Blower, Convection
More frequently depending on the
operating environment
operating environment
OR
X
Door Latch Inspection
Prior to heating season
OR
X
Firebox - Prepare for Non-Burn Season
At end of heating season
OR
X
Firepot - Burning Softwood Pellets
Every 5 bags
OR
X
Firepot - Burning Hardwood Pellets
Every 3 bags
OR
X
Firepot - Burning Alternate Fuels
Every 1 bag
OR
X
Glass
When clear view of fi repot
becomes obscured
becomes obscured
OR
X
Heat Exchanger & Drop Tube
Every 1 ton of fuel
OR
X
Hopper
Every 1 ton of fuel or when chang-
ing fuel types
ing fuel types
OR
X
Venting System
More frequently depending on the
fuel type
fuel type
OR
X