Справочник Пользователя для Quadra-Fire MTVERNINSAE-MBK

Скачать
Страница из 56
Page  4
7036-135G
November 22, 2011
R
Mt. Vernon Pellet Insert (AE)
1
Listing and Code Approvals
A.  Appliance Certifi cation
C.  Glass Specifi cations
E.  BTU & Effi ciency Specifi cations
This appliance is equipped with 5mm ceramic glass.  Replace 
glass  only  with  5mm  ceramic  glass.    Please  contact  your 
dealer for replacement glass.
B.  Mobile Home Approved
NOTE:  This installation must conform with local codes. In 
the absence of local codes you must comply with the ASTM 
E1509-04, ULC S628-93, ULC/ORD-C-1482-M1990 and 
(UM) 84-HUD. 
D.  Electrical Rating
115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps
*BTU output will vary, depending on the brand of fuel you 
use in your appliance.  Consult your Quadra-Fire dealer 
for best results.
MODEL:
Mt. Vernon Pellet Insert AE
LABORATORY:
OMNI Test Laboratories, Inc
REPORT NO.
061-S-69-6
TYPE:
Solid Fuel Room Heater/Pellet Type 
Insert
STANDARD:
ASTM E1509-04, ULC S628-93 and 
ULC/ORD-C1482-M1990 Room Heater 
Pellet Fuel Burning Type and (UM) 84-
HUD, Mobile Home Approved
FCC
Complies with Part 15 of FCC Rules. 
Operation is subject to the following 
two conditions:  (1) this device may not 
cause harmful interference, and (2) this 
device must accept any interference 
received, including interference that 
may cause undesired  operation.
Emissions Rating: EPA Compliant
*BTU Output:
14,620 - 60,200 / hr
Effi ciency:
81.4% - 83.6%
Heating Capacity:
1,775 - 3,089 square feet depend-
ing on climate zone
Hopper Capacity:
56 lbs +/- 5 lbs
Fuel:
Pellets, Shelled Field Corn, Wheat 
and Black Sunfl ower Seeds
Shipping Weight:
425 lbs.
This  appliance  is  approved  for  mobile  home  installations 
when not installed in a sleeping room and when an outside 
combustion air inlet is used.  
The structural integrity of the mobile home fl oor, ceiling, and 
walls must be maintained.  
The appliance must be properly grounded to the frame of 
the mobile home and use only Listed pellet vent Class “L” 
or “PL” connector pipe.  
A Quadra-Fire Outside Air Kit must be installed in a mobile 
home installation. You must order the Outside Air Kit sepa-
rately.
NOTICE:  Hearth & Home Technologies, manufacturer 
of this appliance, reserves the right to alter its prod-
ucts, their specifi cations and/or price without notice.
Quadra-Fire is a registered trademark 
of Hearth & Home Technologies.
WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency 
listing will be voided by the above actions.
DO NOT:
 
•  Install or operate damaged appliance
 
•  Modify appliance
 
•  Install  other  than  as  instructed  by  Hearth  &  Home 
Technologies
 
•  Operate  the  appliance  without  fully  assembling  all 
components
 
•  Overfi re
 
•  Install  any  component  not  approved  by  Hearth  & 
Home Technologies
 
•  Install parts or components not Listed or approved.
Improper  installation,  adjustment,  alteration,  service  or 
maintenance can cause injury or property damage. 
For assistance or additional information, consult a qualifi ed 
installer, service agency or your dealer.
Note:  The appliance is also approved for installation 
into a shop.